  • Page 3 Cotter pin Produktionsbeginn für Indice substitution……………………… Gramolaten, Sorbets oder Warranty certificate…….………. Kalten Getränken First Class Una scelta di qualità…………… Electric system…………….….… Millennium........Istruzioni e avvertenze Millennium electric system ……. Grundlegende generali…………………….……. Refrigerating system…………... Sicherheitsmassnahmen...…….. 60 Installazione del nuovo Exploded view………….……….. Entsorgung der alten apparecchio……………….…….
  • Page 4 Choosing Elmeco, and in with increasing satisfaction A quality choice particular First Class, the and earnings. new and only multifunctional machine with double augers, demonstrates your attention to innovation. Thanks for understanding the importance of working with a company that does not consider “quality”...
  • Page 5 Keep the use and assembly General instruction instructions, even for the next and warnings buyer. The manufacturer declines any responsibility for Before switching on the damages deriving from the non- machine carefully read the observance of the following information in this service instructions.
  • Page 6 Any other usage is to be density thanks to an innovative can be dangerous for the user. considered as improper and electronic control. Before Contact Elmeco for information dangerous. installing the machine, verify concerning the closer that: authorized assistance centre.
  • Page 7 • Rotate the ring nut We do not recommend to Warning! If the plastic parts connect the machine through are washed in the clockwise (pic. 22 e 23 adaptors, multiple plugs and/or dishwashing machine, verify pag. 100) and pull the extensions.
  • Page 8 Outlet restriction Keyboard, augers and cooling First Class controls system block and signals First Class has a new accessory called Restriction It is possible to block the (pic. 28 pag. 100), it is a keyboard. You unblock or block shaped piece that is applied on the buttons by lifting the lamp the ending part of the and pressing the...
  • Page 9 All the functioning modes and Switch on the augers switch the regulations set are Warning: If the temperatures registered in a non-volatile exceed 35° C Elmeco is not memory which is active even responsible for the Press the button in order without power;...
  • Page 10 –5 and 15 for Cold electronic board, the display will Drink Mode, which indicates the show temperature in ° C at which the product must be prepared). ELMECO / ITALIA (0.15) Using you can increase or decrease the Where 0.15 indicates the tank temperature of the product.
  • Page 11 WARNING: If, when the This screen allows you to ByPass electronic board is in Slush activate (LOCK) or deactivate OFF / ON Mode, the product (UNLOCK) the “keyboard lock” In this screen you can activate temperature is greater than function by pressing the or deactivate the bypass 5°...
  • Page 12 temperature alternatively. The The “X” value represent the 1) press the button; 2) the first screen indicates the value critical temperature. In order to first value will start to blink. If of cold drink used in defrost stop stop the warning signal, you want to change the value, mode (set to 7°...
  • Page 13 In order to stop the warning with more messages that Cold drink. appear alternatively. It is possible to change the signal, press the product temperature from –5 to button; thus the count down will How to start the 15 ° C using the start again for the next warning.
  • Page 14 Important security Technical assistance rules The repairing of the machine must be carried out by an • Do not touch the machine authorized service centre, using when you have wet hands only original spare parts. and/or feet. • Do not use the machine with bare feet.
  • Page 15 Important: FCW installation (water cooling system) It is not possible to connect the FCW water entrance with the If the First Class you bought is input of another machine based endowed with the water cooling on a water cooling system system, it is necessary to follow (series).
  • Page 16 First Class Problem Solving Verify that the cable connecting the electronic board to the gear motor magnetic revolution counter is The electronic board displays "1 firmly fixed to both elements. In case it needs to be substituted: disconnect the two connectors of the old cable both from the reader and the electronic board;...
  • Page 17 3° Slip the panel. Pressure switch refit procedure When the pressure switch light, near main switch in ON, 4° Press the button on the pressure switch. Pressure switch light This indicates that the pressure switch intervened to deactivate the compressor. In order to refit this device, it is important to follow the instructions below: 5°...
  • Page 18 In the second case, the hole in With the help of a pliers, fold Cotter pin substitution the gear motor should be the two ends of the split pin completely empty and some downward as indicated by the If the machine works but the remnants of the split pin will arrows in the pic.
  • Page 19 Impianto Electric Installation Elektrik Instalación Elettrico System Electrique Eléctrica - 89 -...
  • Page 20 Impianto Millennium Installation Elektrik Instalación Elettrico Electric Electrique Millennium Eléctrica Millennium System Millennium Millennium - 90 -...
  • Page 21 B: Condensatore P1-2-3: Level 9: Fusible 5x20 rifasamento (FC3 probe mm F315mA 120V/60HZ) 1: Interruttore R1-2-3: Heating EV1-2-3: generale element 100Kohm- Électrovanne Colori 0.25W Pr: Pressostato M1-2-3: BRN Marrone A: Suppressor Motoréducteur LPr: Spia BLU Blu filter (230V/50HZ) pressostato EB1-2-3: Module GRN Giallo-Verde q1-2-3: électronique...
  • Page 22 q1-2-3: EM: Módulo Thermostat máquina 1: Hauptschalter B: Factor H1-2-3: Lector Correction óptico o magnètico Pr: Druckwächter Kondensator (FC3 L1-2-3: Lámpara LPr: 120V/60HZ) cúpula Druckwächter- Kontrollleuchte P1-2-3: Sonda de Farben nivel TM: Timer (Option) BRN Braun R1-2-3: BLU Blau 8: Timer-Taste Resistencia GRN Gelb-Grün C: Kompressor...
  • Page 23 Impianto Refrigerating Installation Kühlanlage Aparato Frigorifero System Frigorifique Frigorífico - 93 -...
  • Page 24 C: Compressore C: Compresseur C: Compresor Cn: Condensatore Cn: Condensateur Cn: Condensador F: Filtro-deidratore F: Filtre-déshydrateur F: Filtro deshidratante B: Boiler B: Ballon B: Boiler ev1: Elettrovalvola ev1: Électrovanne ev1: Electroválvula ev2: Elettrovalvola ev2: Électrovanne ev2: Electroválvula ev3: Elettrovalvola ev3: Électrovanne ev3: Electroválvula E1: Evaporatore E1: Évaporateur...
  • Page 25 Esploso Exploded Vues Explosions Despiece View éclatées darstellung - 95 -...
  • Page 26 LAMPADA 10Watt/12Vac LAMP 10 Watt- 12Vac VTTC2.9X9.5CR VITE TC 2.9X9.5MM CROCE SCREW TC 2.9X9.5 M0005109-001 LAMELLA 12Vac CUPOLA 12V CONTACT FOR TANK M0006129-001 ADESIVO ELMECO CUPOLA PLASTIC LENS STICKER M0006193 CUPOLA TOP LIGHT M0006129-001 ADESIVO ELMECO CUPOLA PLASTIC LENS STICKER M0006125...
  • Page 27 LAMPADA10W AMPOULE 10WATT/12VAC LAMPE 10Watt/12Vac VTTC2.9X9.5CR VIS TC 2.9X9.5MM CRUCIFORME SECHSKANTSCHRAUBE 2.9X9.5MM KREUZ M0005109-001 LAMELLE 12VAC COUPOLE LAMELLE 12Vac SCHUTZHAUBE M0006129-001 AUTOCOLLANT ELMECO COUPOLE KLEBEETIKETT ELMECO SCHUTZHAUBE M0006193 COUPOLE SCHUTZHAUBE M0006129-001 AUTOCOLLANT ELMECO COUPOLE KLEBEETIKETT ELMECO SCHUTZHAUBE M0006125 COUPOLE COMPLÈTE...
  • Page 28 BASE TAPA TRANSPARENTE M0005133-001 PORTALAMPARA LAMPADA10W LAMPARA 10 Watt/12 Vac VTTC2.9X9.5CR TORNILLO TC 2.9X9.5 CR M0005109-001 LAMINILLA 12 Vac BASE TAPA M0006129-001 ADHESIVO ELMECO TAPA M0006193 TAPA DEPOSITO M0006129-001 ADHESIVO ELMECO TAPA M0006125 TAPA DEPOSITO COMPLETA M0000107-001 ABRAZADERA FIJACION PALA VERTICAL M0000108-001...