Dimensions; Installation And Connection; Notes; Heat Pump's Location - Wellness NE100 User And Service Manual

Spa heat pump
Table of Contents

Advertisement

1. Dimensions

2. Installation and connection

2.1. Notes

The factory only supplies the heat pump. All other components must be provided by the
user or the installer.
Attention:
Please observe the following rules when installing the heat pump:
1. Any addition of chemicals must take place in the piping located downstream from
the heat pump.
2. Always place the heat pump on a solid foundation and use the provided rubber
feet to avoid vibration and noise.
3. Always hold the heat pump upright. If the unit has been held at an angle, wait at
least 24 hours before starting the heat pump.

2.2. Heat pump's location

Never install the unit in a closed room with a limited air volume in which the air expelled
from the unit will be reused, or close to shrubbery that could block the air inlet. Such
locations impair the continuous supply of fresh air, resulting in reduced efficiency and
possibly preventing sufficient heat output.
See the drawing below for minimum distances.
12 September 2023/ DH
[Hier eingeben]
Unit:mm
Seite 4 von 26

Advertisement

Table of Contents
loading

Table of Contents