Fault Settings

1) Use Fault? Y
2) Reset Fault
3) Num of Faults = 0
4) Last Fault Time
00/00 2009 00:00
78A
75A
75A
Fault Settings
1) Use Fault? N
2) Reset Fault
3) Num of Faults = 0
4) Last Fault Time
00/00 2009 00:00
79A
76A
76A
Fault Settings
1) Use Fault? N
2) Reset Fault
3) Num of Faults = 0
4) Last Fault Time
00/00 2009 00:00
80A
77A
77A
Fault Settings
1) Use Fault? N
2) Reset Fault
3) Num of Faults = 0
4) Last Fault Time
00/00 2009 00:00
81A
78A
78A
GeoThermal options
1) Heat Pmp Options
2) Geo Settings
3) Fault Settings
4) Backup Settings
5) Heating Priority? N
82A
79A
79A
Backup Settings
1) Use Backup? Y
2) Use Backup Temp
3) Bckup Only Out Temp
4) Bckup Only Tnk Temp
83A
80A
80A
Backup Settings
1) Use Backup? N
2) Use Backup Temp
3) Bckup Only Out Temp
4) Bckup Only Tnk Temp
Page 16
77A Fault Settings: use Fault
Set this to "Y" if you would like to record and see fault conditions.
To use this section you must hook-up faults from the heat pump to pins 5 and 6
on the eCo-1000.
78A Fault Settings: Reset Fault
Set this to clear the most recent fault condition.
79A Fault Settings: Number of Faults
Line three displays the cumulative number of faults that have occurred.
80A Fault Settings: last Fault
Line four indicates the time and date of the last fault.
81A geo options: use Backup
HBX Control Systems Inc. has changed the backup on time. The Geothermal backup will
now activate at 2 times the "Minimum On Time". The "Minimum On Time" is set within
the GEOTHERMAL OPTIONS/HEAT PUMP OPTIONS/ STAGING OPTIONS. This
feature allows the system to attempt to use the heat pumps for a longer duration before
bringing on the backup.
82A Backup Settings: use Backup
Set this option to "Y" if you are using a backup to accompany your heat pumps.
83A use Backup Temp
Set this value to the outdoor temperature that you wish the backup to be enabled. Any
outdoor value below this temperature will allow the backup to turn on when called for.