Operation - Riello RS 68/E ULX Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

Parameter
No.
Description
Error chronology: 701-725.03.Error class
Error chronology: 701-725.04.Phase
Error chronology: 701-725.05.Start-up meter
725
Error chronology: 701-725.06.Load
900
PROCESS INFORMATION
Actual output
903
Index 0 = fuel
Index 1 = air
Position of the servomotors
922
Index 0 = fuel
Index 1 = air
Heat source active
1 = output during the definition of the curves
2 = manual output
942
3 = BACS output
4 = analogue input output
5 = output of the external load regulator contacts
Result of the sampling of the contact (codified in bits)
Bit 0.0 = 1: Minimum pressure switch
Bit 0.1 = 2: Maximum pressure switch
Bit 0.2 = 4: Pressure switch control valves
Bit 0.3 = 8: Air pressure switch
Bit 0.4 = 16: Open load check
Bit 0.5 = 32: ON load check
947
Bit 0.6 = 64: Closed load check
Bit 0.7 = 128: Safety circuit
Bit 1.0 = 1: Safety valve
Bit 1.1 = 2: Ignition
Bit 1.2 = 4: Fuel valve 1
Bit 1.3 = 8: Fuel valve 2
Bit 1.4 = 16: Fuel valve 3/ pilot valve
Bit 1.5 = 32: Reset
Relay request status (coded in bits)
Bit 0 = 1: Alarm
Bit 1 = 2: Safety valve
950
Bit 2 = 4: Ignition
Bit 3 = 8: Fuel valve 1
Bit 4 = 16: Fuel valve 2
Bit 5 = 32: Fuel valve 3/ pilot valve
954
Flame intensity
960
Actual output
961
Status of external modules and visualisation
981
Memory error: Code
982
Memory error: diagnostic code
992
Error indicators
7.5

Operation

Burner without modulating operation kit
Once the start-up cycle is completed, the servomotor command
moves on to the thermostat/pressure switch TR that controls the
pressure or the temperature in the boiler.
 If the temperature or the pressure is low (so the thermostat/
pressure switch TR is closed), the burner progressively
increases the output as far as the MAX value (point " P9").
 If the temperature or the pressure increases as far as the
opening of the thermostat/pressure switch TR, the burner
progressively reduces the output as far as the MIN value
(point "P1"),. The sequence repeats endlessly.
 The burner stops when the heat request is less than the heat
supplied by the burner at MIN output.
20205255
Control and display
Unit of
No. of
Modifica-
measure-
elements
tion
ment
25
-
Reading only
25
-
Reading only
25
-
Reading only
25
%
Reading only
2
%
Reading only
2
(°)
Reading only
1
-
Reading only
2
-
Reading only
1
-
Reading only
1
%
Reading only
3
m
/h, l, h,
1
Reading only
3
ft
/h, gal/h
1
-
Reading only
1
-
Reading only
1
-
Reading only
10
-
Reset
 The thermostat/pressure switch TL opens, the flame control
carries out the switching off phase.
 The air damper closes completely to reduce heat losses to a
minimum.
Burner with modulating operation kit
See manual enclosed with the adjuster kit.
50
GB
Values interval
Degree of
precision
Min.
Max.
0
6
1
0
255
1
0
99999999
1
0%
100%
0.1%
0%
100%
0.1%
-50°
150°
0.01°
0
255
1
0
255
1
0
255
1
0%
100%
1%
0
6553,5
0,1
0
255
1
0
255
1
0
255
1
0xFFFFFF
0
1
FF
Predefined
Access mode
setting
0
Info mode
0
Info mode
0
Info mode
0%
Info mode
0%
Info mode
Info mode
0
Service mode
0
Info mode
0
Info mode
0%
Info mode
0
Info mode
0
Info mode
0
Info mode
0
Info mode
0
Service mode
Tab. P