SWIRLFLO
®
INSTALLER
NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices to
available water lines. This can, however, cause electrical feedback in the plumbing circuit, which results in
an "electrolysis" effect occurring in the fountain. This may result in water which has a metallic taste to it or
has a noticeable increase in the metallic content of the water.
When inspecting plumbing circuit, remember the line may be grounded some distance from the
installation, and may occur outside the building or area in which the unit is being installed.
This condition can be avoided (in most cases) by using recommended materials during installation.
Any drain fittings provided by the installer should be made of plastic which will electronically isolate the
fountain from the remainder of the building's plumbing circuits.
INSTALLATION & USE MANUAL
Refrigerated fountains with FLEXI-GUARD
Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.
When installation is complete, ensure these instructions are left with building owner
for future reference.
Service to be performed by authorized service personnel only.
ENOB8C
Page 1
®
98004C (REV. C - 02/18)

Advertisement

loading

Summary of Contents for Elkay SWIRLFLO ENOB8C

  • Page 1 ENOB8C INSTALLATION & USE MANUAL SWIRLFLO Refrigerated fountains with FLEXI-GUARD ® ® INSTALLER Review these instructions before beginning installation. Be sure that installation conforms to all plumbing, electrical and other applicable codes. When installation is complete, ensure these instructions are left with building owner for future reference.
  • Page 2 ENOB8C Model ENOBM8C 3 1/8" 79mm 1 1/8" 29mm 9 3/8" 8 1/8" 238mm 206mm 12" 305mm MINIMUM DEPTH 18 3/8" 5/8" BACK WALL LINE 467mm 16mm 1 5/8" 41mm 33 15/16" 863mm 28 3/4" 27" 730mm 686mm REQUIREMENT 8" 203mm 4 1/2"...
  • Page 3: Required Tools And Materials

    ENOB8C REQUIRED TOOLS AND MATERIALS These tables show special tools and/or additional materials (not provided) which are necessary to complete installation of these units: Special Tools Item Description Quantity NONE Additional Materials Item Description Quantity Unplated copper inlet pipe Service Stop 1.
  • Page 4 ENOB8C 10. Connect power cord of sensor to solenoid valve assembly by running it through the back panel and connecting it to termianl shown in Fig. 8. 11. Turn on water supply and check for leaks. Release air from tank by interrupting infrared beam;...
  • Page 5 ENOB8C CONNECT TO FOUNTAIN SENSOR WIRING CONNECTOR 2, 3, 4 Figure 7 - Solenoid Assembly Figure 8 - Regulator Assembly (Item 8) See Fig. 10 BASIN Locknut NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN LOCKNUT ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN.
  • Page 6: Parts List

    CAUTION: Complete range of sensor (24 - 46 inches) is only one turn of the adjusting screw. c) Replace Lens. FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816 REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640 ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484 • www.elkay.com Page 6 98004C (REV. C - 02/18)