Belden Lumberg Automation 0970 PSL 650 Technical Manual
Belden Lumberg Automation 0970 PSL 650 Technical Manual

Belden Lumberg Automation 0970 PSL 650 Technical Manual

Lion-s i/o modules

Advertisement

Quick Links

LioN-S I/O modules
Technical Manual
0970 PSL 650 | 0970 PSL 651

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Lumberg Automation 0970 PSL 650 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Belden Lumberg Automation 0970 PSL 650

  • Page 1 LioN-S I/O modules Technical Manual 0970 PSL 650 | 0970 PSL 651...
  • Page 2 Technical Manual 0970 PSL 650 | 0970 PSL 651 LioN-S I/O modules for Profibus 0970 PSL 650 0970 PSL 651 8 digital channels (p-switching), 8 digital inputs (p-switching), channels can be used universally as inputs or with rotary address switches outputs, with rotary address switches Version 1.00 / 2007-Sept-03 Specifications subject to alteration!
  • Page 3 0970 PSL 650 | 0970 PSL 651 1. About this Manual Please read the assembly and operating instructions Lumberg Automation – Belden Deutschland GmbH in this Manual carefully before putting the LioN-S Im Gewerbepark 2 type module into operation. The Manual should be 58579 Schalksmühle...
  • Page 4: Qualified Personnel

    Technical Manual 0970 PSL 650 | 0970 PSL 651 The error-free, secure operation of the product prevention regulations that apply to the specific requires proper transport, storage, set-up and activity being performed during project planning, assembly, as well as careful operation. The intended installation, commissioning, maintenance and test- operation of the device can only be guaranteed ing of the devices.
  • Page 5 Technical Manual 0970 PSL 650 | 0970 PSL 651 3. Pin assignment Connection Function 3.1 Profibus-DP M12 male/female connector +5 V* poles, B-coded Profibus DP Line A In/Out GND* Line B earth The signals marked with * are internal signals which the module provides for supplying a terminator.
  • Page 6: Profibus Network

    Technical Manual 0970 PSL 650 | 0970 PSL 651 4. Communication with the module 4.1 Addressing Rotary address switches Two rotary switches, located above the M12 bus con- nections behind a clear cover, are used for direct adjustment of the Profibus address. The switches for setting the tens and the ones of the address are indicated.
  • Page 7 Technical Manual 0970 PSL 650 | 0970 PSL 651 a) Configuration example in the Siemens Company's S7 Software Integration of the module onto the Profibus line Selection and entry of the configuration Version 1.00 / 2007-Sept-03 Specifications subject to alteration! Page 7 of 17...
  • Page 8 Technical Manual 0970 PSL 650 | 0970 PSL 651 Display of the selected configu- ration (here: 0970 PSL 650 as Universal 8 DI/8 DO) Display of the selected configu- ration (here: 0970 PSL 650 as 8 DO) Version 1.00 / 2007-Sept-03 Specifications subject to alteration! Page 8 of 17...
  • Page 9 Technical Manual 0970 PSL 650 | 0970 PSL 651 b) Configuration example CoDeSys of the 3S Software Solutions Co. (Moeller) Select module from the list Automatic address reservation (can be modified by the user) Version 1.00 / 2007-Sept-03 Specifications subject to alteration! Page 9 of 17...
  • Page 10 Technical Manual 0970 PSL 650 | 0970 PSL 651 Automatic allocation of the module address (can be modified by the user) Mark the desired type and select with the button Version 1.00 / 2007-Sept-03 Specifications subject to alteration! Page 10 of 17...
  • Page 11 Technical Manual 0970 PSL 650 | 0970 PSL 651 Byte-to-byte display of the addresses of the selected configuration Bit-to-bit display of the addresses of the selected configuration The 0970 PSL 650 module can be used as a simple input/output module as well as a mixed input/output module.
  • Page 12: Bit Assignment

    Technical Manual 0970 PSL 650 | 0970 PSL 651 4.4 Bit assignment The Profibus telegram permits transmission of a maximum of 244 bytes of information data. Depending on utilization of the 0970 PSL 650 mod- ule, the information data with these modules con- sists of one or two bytes;...
  • Page 13: Manufacturer Identification

    Technical Manual 0970 PSL 650 | 0970 PSL 651 b) Profibus network In case of an error Profibus devices send a diagnostic content cannot be altered. The user-specific diagnos- message to the Master (sensor/actuator short circuit, tics begins with byte 6. undervoltages).
  • Page 14: Id-Related Diagnostics

    Technical Manual 0970 PSL 650 | 0970 PSL 651 Bit no. Byte 6 0 1 0 0 0 0 1 0 length (2 Byte) Header ID-related diagnostics Bit no. Byte 7 0 1 0 0 0 0 1 0 Socket 1 Periphery fault Socket 2 Periphery fault Socket 3 Periphery fault Socket 8 Periphery fault...
  • Page 15 Technical Manual 0970 PSL 650 | 0970 PSL 651 Principles behind the structure of the channel diagnostics Bit no. Byte 10 1 0 0 0 0 0 0 0 000001 to 001000 : ID number of the module which provides the channel -related diagnostics. The plug -in position of the module is coded.
  • Page 16: Technical Data - Inputs

    Technical Manual 0970 PSL 650 | 0970 PSL 651 5. Technical data 5.1 General data 5.5 Technical data – Inputs Degree of protection IP 67 Input circuit Type 3 according to (only in locked position) IEC 61131-2 Operating temperature range -10°C / +60°C Rated input voltage 24 V DC...
  • Page 17 Technical Manual 0930 DSL 700 | 0930 DSL 701 Technical Manual 0970 PSL 650 | 0970 PSL 651 Lumberg Automation – Belden Deutschland GmbH Lumberg Automation Support & Service Lumberg Automation – Belden Deutschland GmbH Lumberg Automation Support & Service...