Page 55
The commands listed below are available. Type 'help' to see this list. Most commands can be called without an argument and return the current setting. preset [<store|recall> [<num>]]: store/recall preset number <num> volume [<vol>|+|-]: Sets the volume of the monitor output (0-99) monitor [<source>:<channel>]: Sets the source of the monitor output Available sources: AES3ADAT,MADISFP1,MADISFP2,MADICOAX,AES50TP1,AES50TP2, DANTE1,DANTE2,FLEXLINK1,FLEXLINK2,FLEXLINK3 channels:1-64...
Page 56
(>)right (l): lock the front panel (u): unlocks the front panel (_): a dash preceding the key means 'long press' version: Retrieves device version id: Retrieves device version in JSON-Format (same as "config i") config [query] [<json_string>]: Set and/or get device config in JSON format. 'query' can be left out or any combination of what to get: query changes only since last call, must be specified as first flag in combination with any of the letter options listed below.