S&C CS-1A Manual
S&C CS-1A Manual

S&C CS-1A Manual

Switch operator
Hide thumbs Also See for CS-1A:

Advertisement

Quick Links

S&C Type CS-1A Switch Operator★
Outdoor Transmission

Table of Contents

Introduction � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
Qualified Persons � � � � � � � � � � � � � � � � � � � � � � � � � � � 2
Read this Instruction Sheet � � � � � � � � � � � � � � � � � � � 2
Retain this Instruction Sheet� � � � � � � � � � � � � � � � � � � 2
Proper Application � � � � � � � � � � � � � � � � � � � � � � � � � � 2
Warranty � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 3
Safety Information � � � � � � � � � � � � � � � � � � � � � � � � 4
Understanding Safety-Alert Messages � � � � � � � � � � � 4
Following Safety Instructions � � � � � � � � � � � � � � � � � � 4
Replacement Instructions and Labels � � � � � � � � � � � 4
Location of Safety Labels � � � � � � � � � � � � � � � � � � � � � 5
Safety Precautions � � � � � � � � � � � � � � � � � � � � � � � 6
Overview � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 7
★ For use with the Mark V Circuit-Switcher
November 13, 2023
© S&C Electric Company 1978-2023, all rights reserved
Operation
Operation � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 10
Electrical Operation � � � � � � � � � � � � � � � � � � � � � � � � �11
Manual Operation � � � � � � � � � � � � � � � � � � � � � � � � � �12
Post Operating Inspection � � � � � � � � � � � � � � � � � � � �13
Switcher to Normal Operation � � � � � � � � � � � � � � �13
Decoupling) � � � � � � � � � � � � � � � � � � � � � � � � � � � � �14
Inspection and Maintenance � � � � � � � � � � � � � � 16
Elective Exercising � � � � � � � � � � � � � � � � � � � � � � � � � �16
Brake Inspection � � � � � � � � � � � � � � � � � � � � � � � � � � � �16
Superseded-Design Switch Operators � � � � � � � �19
Instruction Sheet 719-501

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CS-1A and is the answer not in the manual?

Questions and answers

Summary of Contents for S&C CS-1A

  • Page 1: Table Of Contents

    S&C Type CS-1A Switch Operator★ Outdoor Transmission Operation Table of Contents Introduction � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 2 Operation �...
  • Page 2: Introduction

    PDF format at https://www�sandc�com/en/ contact-us/product-literature/� Retain this This instruction sheet is a permanent part of the Type CS-1A Switch Operator. Designate a location where users can easily retrieve and refer to this publication. Instruction...
  • Page 3: Warranty

    Introduction Warranty The warranty and/or obligations described in S&C’s Price Sheet 150, “Standard Conditions of Sale–Immediate Purchasers in the United States,” (or Price Sheet 153, “Standard Conditions of Sale–Immediate Purchasers Outside the United States”), plus any special warranty provisions, as set forth in the applicable product-line specification bulletin, are exclusive.
  • Page 4: Safety Information

    Safety Information Understanding Several types of safety-alert messages may appear throughout this instruction sheet and on labels and tags attached to the Type CS-1A Switch Operator. Become familiar with these types Safety-Alert of messages and the importance of these signal words:...
  • Page 5: Location Of Safety Labels

    Safety Information Location of Safety Labels Reorder Information for Safety Labels Location Safety Alert Message Description Part Number CAUTION Use pushbuttons to open or close the circuit-switcher���� G-4527R3 NOTICE The S&C Instruction Sheet is a permanent part of your S&C Equipment���� G-3733R2 NOTICE Auxiliary switch cams are individually adjustable�...
  • Page 6: Safety Precautions

    The vertical operating shaft SAFETY PROCEDURES� Always follow safe 2� above the Type CS-1A Switch Operator must also operating procedures and rules� be connected to a suitable earth ground� PERSONAL PROTECTIVE EQUIPMENT� Always 3�...
  • Page 7: Overview

    Overview The Type CS-1A Switch Operator is a high-speed operator having an operating time of 1.5 seconds maximum. It is expressly designed for power operation of Mark V Circuit-Switchers. High-speed, high-torque power operation of Mark V Circuit-Switchers, by means of the Type CS-1A Switch...
  • Page 8 Overview Interrupter targets Circuit-switcher position indicator Manual operating handle Pushbutton protective cover Latch Selector knob handle Door handle Figure 1� A 69-kV integer-style Mark V Circuit-Switcher connected to a Type CS-1A Switch Operator� S&C Instruction Sheet 719-501...
  • Page 9 Duplex receptacle and drums lampholder with switch Shunt-trip fuseholder Instruction book holder Motor circuit fuseholder Space heater fuseholder Door gasket Filter holder Figure 2� An interior view of a Type CS-1A Switch Operator with the door open� S&C Instruction Sheet 719-501...
  • Page 10: Operation

    S&C Instruction Sheet 719-500, “S&C Type CS-1A Switch Operators: Installation.” Figure 1 on page 7 illustrates a Type CS-1A Switch Operator connected to an integer-style Mark V Circuit-Switcher.
  • Page 11: Electrical Operation

    Operation Electrical Operation To open or close the circuit-switcher electrically: Protective cover STEP 1� Unlock and lift the external pushbutton protec- tive cover. See Figure 4. Pushbuttons STEP 2� Press the appropriate pushbutton. Note: The switch operator may be activated by operating associated, remotely located control switches.
  • Page 12: Manual Operation

    Operation Manual Operation To open the circuit-switcher manually, follow these steps: WARNING Manually closing an energized circuit-switcher is not recommended because of the possibility of closing into a fault� Manually opening an energized circuit-switcher is permissible� When the opening operation has been Latch initiated, however, it should be completed quickly and knob...
  • Page 13: Post Operating Inspection

    Operation STEP 4� To return the manual operating handle to its when the interrupter is open. The target appears gray Storage position, pull the latch knob and pivot (normal) when the interrupter is closed. the handle approximately 90 degrees. The handle Because the interrupters are closed as the circuit- will then be disengaged from the switch operator switcher blades move to the fully Open position, the target...
  • Page 14: Using The Selector Handle

    Operation Using the Selector Handle (Coupling and Decoupling) The integral external selector handle used to operate the built-in internal decoupling mechanism is located on the right-hand side of the switch operator enclosure. Become familiar with the operation of the selector handle, as described on the switch operator nameplate on the right- hand side of the enclosure.
  • Page 15 Operation To couple the switch operator to the circuit- switcher: Manually operate the switch operator to bring STEP 1� it to the same position (Open or Closed) as the circuit-switcher. The switch operator position indicator, seen through the observation window, will show when the approximate Open or Closed position has been attained.
  • Page 16: Inspection And Maintenance

    Circuit-Switcher: Inspection Recommendations,” the brake (19 mm), as shown in Detail B in Figure 8 on in the Type CS-1A Switch Operator should be inspected page 17. Now, tighten the 3/32-inch pad assembly every 2,500 operations or five years, whichever occurs socket-head set screw.
  • Page 17 Inspection and Maintenance STEP 10� Check the operation of the brake linkage as follows: (a) Pull the latch knob on the hub of the manual operating handle and slowly pivot the handle forward from its Storage position toward its Cranking position until the brake disc can be rotated by hand.
  • Page 18 Inspection and Maintenance Motor shaft square key Pad assembly socket- head set screw (3/32-inch Allen wrench Brake required) disc Brake lever Angle bracket 1/4–20-inch socket-head set screw (1/8-inch Allen wrench required) 5/16–20 x 11/4-inch DETAIL C hex-head screw Location of Motor Shaft Set Screw (115 5/16-inch socket- &...
  • Page 19: Recommended Exercising Procedure For Superseded-Design Switch Operators

    Inspection and Maintenance Recommended Exercising Procedure for STEP 4� Open the control-source disconnect switch and reconnect wires numbered 8C and 8D to the OC Superseded-Design Switch Operators coil terminal C7. (catalog numbers 38846 through 38846R3, equipped with optional shunt-trip solenoid switch and redun- To exercise the redundant (62) relay: dant relay [catalog number suffix “-HP”]) STEP 1�...

Table of Contents