Replacing Infrared Humidifier La
mps of the NetCol8000-A050 (3)
Copyright © 2017 Huawei Technologies Co., Ltd. All rights reserved.
Step 6 Remove the water pan and
the lamp tube, as shown in Figure;
Step 7 Take out the lamp tube and
install a new one;
Step 8 Reassemble the infrared
humidif er in an inverse order of Step
2 to Step 6;
Step 9 Power on the unit and tap
Maint > Diagnostic Mode >
Enter, open the solenoid valve and
the humidif er. Make sure they work
properly. Exit the Diagnostic Mode.
Step 10 Tap Maint >
Performance Maint to clear the
humidif er total runtime.