PLAYBACK MALFUNCTION
No
playback
Playback hissing
noise
Loss
of high frequencies
Channels
unbalanced
during
playback
Crosstalk
between
forward
and
reverse
tracks
RECORD
MALFUNCTION
No
record
Loss
of high
frequencies
during
record
No
erase
No VU light
Channels
not balanced
during
record
CHECK
POINT
MONITOR
switch
is in SOURCE.
Interconnecting
cords
out
or
loose.
Head
dirty
or
defective.
Playback
ampl.
circuit.
PLAYBACK
control
is
set
position.
Improper
program
level
during
record.
NOTE:
A highly
efficient
tweeter
in
the
speaker
system
will
cause
hiss
to
be prominent.
Decrease
tweeter
level,
record
at a higher
level.
Tape
faulty.
Heads
dirty.
Heads worn
or out
of AZIMUTH
alignment.
Tape
faulty.
Heads
dirty.
Heads
worn.
Playback
level
adjustment.
Head
switching
relay
K-7.
Head out
of alignment.
Interconnecting
cables
loose
or
out.
Heads
dirty.
Record
ampl.
circuit.
Bias
oscillator
assy.
7
Head
dirty.
Tape
tension
incorrect.
Tape
faulty.
Bias
adj.
improper.
Erase
head
dirty.
Bias
oscillator
assy.
To replace
the lamp.
Procedure:
Turn
off
power,
pull
off
the
plastic
VU meter
cover.
Fold
the
wires
holding
the
lamp
forward.
Folder
in new
lamp with
low heat
iron.
Fold wires
back.
Replace
cover.
Head
dirty
or
improper
bias.
Out
of adjustment.
Improper
record
level
calibration.