Summary of Contents for THERMOROSSI SLIMQUADRO 11 STYLE

  • Page 1 Installation, use and maintenance guide. Model QUADRO11EVOE with casing: - SLIMQUADRO 11 STYLE...
  • Page 2 Installation, use and maintenance guide QUADRO11EVOE Page 1...
  • Page 3: Table Of Contents

    Installation, use and maintenance guide QUADRO11EVOE INDEX 1 – INTRODUCTION..........................5 2 – TECHNICAL CHARACTERISTICS...................... 7 3 – GENERAL DESCRIPTION ........................8 4 – INSTALLATION ........................... 8 5 – DESCRIPTION OF THE CONTROLS ....................13 6 – USE OF THE APPLIANCE .........................19 7 - ADDITIONAL ROOM TEMPERATURE THERMOSTAT / ADDITIONAL CHRONOTHERMOSTAT- MODEM ..............................20 8 - CLEANING AND MAINTENANCE ......................22...
  • Page 4 Name and address of the agent as required pursuant Article 12( 2): THERMOROSSI S.P.A. Via Grumolo, n° 4 36011 Arsiero (VI) Sistema di valutazione e verifica della costanza della prestazione del prodotto da costruzione di cui all'allegato V: Sistema 3 e 4...
  • Page 5 IT – MARCHIO EN – PRODUCT FICHE (EU 2015/1186) EN – BRAND FR – FICHE PRODUIT (UE 2015/1186) FR – MARQUE THERMOROSSI S.P.A. NL – PRODUCTGEGEVENSBLAD (EU 2015/1186) NL – MERK DE – PRODUKTDATENBLATT (EU 2015/1186) DE – MARKE ES – FICHA DE PRODUCTO (UE 2015/1186) ES –...
  • Page 6: Introduction

    Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
  • Page 7 Installation, use and maintenance guide QUADRO11EVOE ATTENTION: Before every use make sure that the burner is clean and positioned correctly in its seat, check that the ash pan is clean and that the firebox door is firmly closed and tight. ATTENTION: the door must always remain shut tight when the appliance is operating.
  • Page 8: Technical Characteristics

    Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p Prodotto USCITA FUMI Il presente disegno è di proprietà esclusiva di THERMOROSSI S.p.A.. La riproduzione totale e/o parziale e la divulgazione a terzi, senza nostro esplicito consenso scritto, verrà perseguito seco PRESA ARIA Note...
  • Page 9: General Description

    Installation, use and maintenance guide QUADRO11EVOE 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance. 3.2 THE PELLET The appliance is fuelled by pellets, that is, cylinders of compressed sawdust;...
  • Page 10 Revisione: realizzare qualsiasi attrezzatura, fornire a piano deve essere verificato ed eventualmente modificato dal THERMOROSSI S.p.A. i file fornitore in funzione delle macchine di piegatura che tridimensionali dei particolari definitivi andranno a realizzare il particolare.
  • Page 11 Installation, use and maintenance guide QUADRO11EVOE Figura 1 To glue the panes to the front panel, firstly apply silicone to the surface of the panel as illustrated in Figure 1. Attention: as highlighted in detail C, do not apply silicone to the areas where the corners of the glass cross over. If applied here the silicone could leak out and ruin the look of the product.
  • Page 12 Installation, use and maintenance guide QUADRO11EVOE 4.6 HANDLE Your appliance is supplied with a handle for opening and closing the firebox door to facilitate cleaning (see dedicated paragraph). The handle is also designed to be used for regulating the channelling flow rate. When not in use, the handle can be stowed on the side of the appliance if the hook provided is attached to the appliance.
  • Page 13 Installation, use and maintenance guide QUADRO11EVOE Legenda CANALIZZAZIONE CHANNELLING USCITA FUMI SMOKE OUTLET PRESA ARIA AIR INTAKE CANALIZZAZIONE USCITA FUMI PRESA ARIA Fix the bracket on the wall and hang the unit on the wall bracket; it is recommended to push it firmly against the wall and tighten the fixing screws B.
  • Page 14: Description Of The Controls

    Installation, use and maintenance guide QUADRO11EVOE 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
  • Page 15 Installation, use and maintenance guide QUADRO11EVOE Display The following information can appear on the display: Displays the pre-set combustion power, and consequently the pellet consumption, by the number of bars that are lit up around the flame symbol, using this logic: One bar lit up: Minimum combustion power (and therefore with minimum pellet consumption) Two bars lit:...
  • Page 16 Installation, use and maintenance guide QUADRO11EVOE After a few seconds the following screen will appear on the display: 2) Now press the Scroll Buttons to change the day of the week; each dot corresponds to one day of the week (e.g., 1 corresponds to Monday, 2 correspond to Tuesday, etc...).
  • Page 17 Installation, use and maintenance guide QUADRO11EVOE 4) Now press the Scroll Buttons to select the hour at which you wish the appliance to shut off automatically (OFF1). Once the hour has been set, confirm the value by pressing the Flame Button. Once confirmed, the selector shifts to the flashing minute section of OFF1.
  • Page 18 Installation, use and maintenance guide QUADRO11EVOE Using the same logic, we can copy the programmed cycles to the other days. 7) To conclude the programming operations simply press the Menu Button to exit the screen, and the initial screen will appear. ATTENTION: The appliance ignores any ON or OFF command programmed with a value of 00:00.
  • Page 19 Installation, use and maintenance guide QUADRO11EVOE After a few seconds the following screen will appear on the display: To change the operating level, hold down a Scroll Button while simultaneously pressing the other Scroll Button. To set the desired level or to exit the screen simply press the Menu Button; the initial screen will appear on the display.
  • Page 20: Use Of The Appliance

    Installation, use and maintenance guide QUADRO11EVOE 6 – USE OF THE APPLIANCE 6.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
  • Page 21: Additional Room Temperature Thermostat / Additional Chronothermostat-Modem

    Installation, use and maintenance guide QUADRO11EVOE LEVERISMO MANOPOLA MANOPOLA Manopola LEVERISMO MANOPOLA MANOPOLA Manopola Leverismo COLLARINO COLLARINO VITE VITE Tappo VITE Tappo VITE Leverismo Leverismo Legenda MANOPOLA KNOB LEVERISMO LEVER The air can be distributed from the front, side or back. Tappo Plug •...
  • Page 22 ATTENTION: Use N.O. (normally open) contacts for the connection to the chrono-thermostat. ATTENTION: In the event of connections to the chrono-thermostat Thermorossi shall not be held responsible for the appliance not starting up, smoke leaks and breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
  • Page 23: Cleaning And Maintenance

    Installation, use and maintenance guide QUADRO11EVOE 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD Before commencing any operation disconnect the appliance from the electric power outlet. Your pellet appliance needs maintenance; it requires a few simple, basic but frequent control and general cleaning operations. This will guarantee safe and regular operation and optimal output at all times.
  • Page 24 Installation, use and maintenance guide QUADRO11EVOE Blade AT THE END OF THE WINTER SEASON OR WHENEVER NECESSARY Do an in-depth cleaning of the appliance firebox, with brushes and a vacuum cleaner. Using a vacuum device simplifies cleaning out the ashes. Use a damp cloth or a scrunched-up piece of newspaper, dampened and rolled in the ash, to wipe the glass until it is perfectly clean.
  • Page 25 Installation, use and maintenance guide QUADRO11EVOE Page 24...
  • Page 26 Installation, use and maintenance guide QUADRO11EVOE 8.3 AIR FILTER Your appliance is fitted with an air filter; a practical device that prevents the circulation of dust particles that are always present in domestic environments. The filter (shown in the image below) is installed in the bottom right part of the appliance. Frequent cleaning will ensure greater availability of hot air during operation and less overheating of the appliance.
  • Page 27 Installation, use and maintenance guide QUADRO11EVOE Legenda Batteria Tampone CR 1632 Buffer battery CR 1632 This operation must be exclusively performed by qualified professional staff, as set forth by Decree no. 37 of 22nd January 2008 and applicable laws on the subject. Before performing said task, make sure the power supply cable is disconnected from the electrical power socket.
  • Page 28: Smoke Discharge Tube And Ventilation Of The Rooms

    Installation, use and maintenance guide QUADRO11EVOE 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
  • Page 29 Installation, use and maintenance guide QUADRO11EVOE 9.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS 1 Chimney 2 Flow path Every chimney must have minimum number of components as laid down by standard UNI EN 1443 3 Smoke discharge tube which are also indicated in the figure on the left. 4 Thermal insulation 5 External wall 6 Outer lining...
  • Page 30 Installation, use and maintenance guide QUADRO11EVOE THE FLUE OUTLET MUST BE USED ONLY FOR THE APPLIANCE. It must be possible to inspect and remove all the smoke tube sections for clean-out purposes. ATTENTION: if the flue outlet is not sufficiently insulated and /or if it is too long it could generate condensation. It is mandatory to provide a condensation drain near the smoke outlet of the appliance.
  • Page 31: Alarms

    ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
  • Page 32: Electrical Wiring

    Installation, use and maintenance guide QUADRO11EVOE 11 - ELECTRICAL WIRING LEGENDA TERMOSTATO AMBIENTE (Optional) ROOM THERMOSTAT (optional) MODEM (Optional) MODEM (Optional) TERMOSTATO 95°C THERMOSTAT 95°C MOTORIDUTTORE SPIA VERDE GEARMOTOR GREEN INDICATOR LIGHT SONDA FUMI SMOKE SENSOR PANNELLO COMANDI CONTROL PANEL ENCODER ENCODER PRESSOSTATO...
  • Page 33: Information For The Skilled Technician

    Installation, use and maintenance guide QUADRO11EVOE 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
  • Page 34 Installation, use and maintenance guide QUADRO11EVOE 12.3 TROUBLESHOOTING CAUSE-SOLUTION PROBLEM POSSIBLE CAUSE SOLUTION CLEAN THE BRAZIER AS INDICATED IN THIS USE AND PELLET TANK IS EMPTY MAINTENANCE GUIDE, THEN FILL UP THE TANK WITH THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY “NO PELLET” PELLETS PELLET SCREW FEEDER BLOCKED BY FOREIGN OBJECT SUCH AS NAIL, NYLON, PIECE CUT OFF THE POWER AND REMOVE THE FOREIGN OBJECT...
  • Page 35 Installation, use and maintenance guide QUADRO11EVOE THE BRAZIER EXCESSIVE DRAUGHT IN THE FLUE OUTLET HAVE THE FLUE OUTLET DRAUGHT CHECKED AND IF THE FOLLOWING ALARM IS SHOWN ON THE DISPLAY “NO PELLET” NECESSARY MAKE THE APPROPRIATE MODIFICATIONS THE TIME DOES NOT THE BUFFER BATTERY INSTALLED IN THE CONTROL PANEL IS EXHAUSTED REPLACE THE BATTERY REMAIN IN THE MEMORY...
  • Page 36 Installation, use and maintenance guide QUADRO11EVOE F ire L o v e rs Via Grumolo, 4 (Z.I.) 36011 Arsiero (VI) - ITALY Fax 0445.741657 - www.thermorossi.com - info@thermorossi.it Page 35...