INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 INDEX 1 – INTRODUCTION..........................5 2 – TECHNICAL CHARACTERISTICS...................... 7 3 – GENERAL DESCRIPTION ........................8 4 - INSTALLATION ........................... 9 5 – DESCRIPTION OF THE CONTROLS ....................14 6 – USE OF THE APPLIANCE .........................21 7 –...
Page 4
DECLARATION OF PERFORMANCE ACCORDING TO REGULATION (EU) 305/2011 Codice di identificazione unico del prodotto-tipo: SLIMQUADRO 9 Modello, lotto, serie ai sensi dell'articolo 11, paragrafo 4: SLIMQUADRO 9 Unique identification code of the product type: Model, batch or serial number required under Article 11(4):...
Page 5
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Arsiero, 16/04/2014 IT – SCHEDA PRODOTTO (UE 2015/1186) IT – MARCHIO EN – BRAND EN – PRODUCT FICHE (EU 2015/1186) FR – FICHE PRODUIT (UE 2015/1186) FR – MARQUE THERMOROSSI S.P.A. NL – PRODUCTGEGEVENSBLAD (EU 2015/1186) NL –...
Furthermore, Thermorossi reserves the right to apply changes to the content of this manual anytime and without notice. Thermorossi S.p.A. retains copyright on this manual. These instructions may not be reproduced or communicated to third parties or used in any other way without the necessary authorisation.
Page 7
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 The product must not be used by children under the age of 8 years, by persons with physical, mental or sensorial impairments, or by persons who are not familiar with the instructions for use and maintenance of the product (the instructions are found in this booklet).
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 3 – GENERAL DESCRIPTION 3.1 OPERATING TECHNOLOGY Your appliance has been built to fully satisfy all your heating and practical requirements. Top-grade components and functions managed with microprocessor technology guarantee high reliability and optimal performance.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 4 - INSTALLATION 4.1 APPLIANCE LOCATION Follow the general guidelines set out in paragraph 1.1 to the letter. Keep in mind that the flooring of the room in which the appliance is to be installed must withstand the total weight of the appliance combined with the pellets contained in the tank and the weight of the casing.
Page 11
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 4.3 GLUING THE GLASS PANES TO THE FRONT PANEL After unpacking the glass panes of the casing, disassemble the front panel as described below. Prior to beginning any operation, lay a soft sheet on the floor where you can place the front panel after removing it from the appliance, in order to prevent damaging the floor or scratching the paint on the panel.
Page 12
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 4.4 CONNECTING THE APPLIANCE TO THE FLUE OUTLET Connection of the appliance to the flue outlet must be carried out in strict compliance with the instructions contained in this booklet (see Chapter 9).
Page 13
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 To mount the hook, remove the right side panel 1 of the heater (see paragraph 4.3), position the hook 2 in the hole and lock with the nut 3. Replace the side panel 1.
Page 14
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Hang the unit on the wall bracket A; once the appliance is suspended, push it firmly against the wall and tighten the screws B. When carrying out this operation, take care to match up the support hooks (See details C and D in Figure 7).
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 5 – DESCRIPTION OF THE CONTROLS The appliance, when operating, could be hot to the touch, particularly the door of the combustion chamber: take care when handling the appliance components. Your appliance has obtained the CE marking and has been made to run for at least one hour to check that it functions correctly.
Page 16
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Displays the preset combustion power, and consequently the pellet consumption, by the number of bars that are lit up around the flame symbol, using this logic: One bar lit up: Minimum combustion power (and therefore with minimum pellet consumption)
Page 17
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 1) Press the Menu Button once to view the following screen: After a few seconds the following screen will appear on the display: 2) Now press the Scroll Buttons to change the day of the week; each dot corresponds to one day of the week (e.g. 1 corresponds to Monday, 2 correspond to Tuesday, etc...).
Page 18
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 3) Now press the Scroll Buttons to select the hour at which you wish the appliance to start up automatically (ON1). Once the hour has been set, confirm the value by pressing the Flame Button.
Page 19
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Alternatively, if you wish to copy the exact same programming for the ON/OFF cycles set for a particular day to the next day simply press the Ventilation button. For example: if I want to copy all the programmed ON/OFF cycles set for Monday to Tuesday the following screen will appear: I press the Ventilation button once again to copy all the cycles programmed for Tuesday to Wednesday.
Page 20
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 5.5 LEVEL: OPERATING LEVEL SETTING The appliance must be energised and the I/0 switch in position “I". Your appliance is delivered with an excellent program installed that favours combustion efficiency; the program is called LEVEL 1.
Page 21
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 2) Press the left Scroll Button repeatedly to scroll and consult the programmings for all the days of the week. Attention: the on-off programmings cannot be modified from the SHOW CRONO menu. This menu is used only for viewing the programs that have been entered and/or edited through the “CHRONO” menu.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 6 – USE OF THE APPLIANCE 6.1 DESCRIPTION OF THE OPERATING STAGES START: has a duration of approx. 20 minutes, during this phase the appliance is programmed to light the flame. The appliance will not accept power variations in the firebox.
Page 23
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Use pipes with smooth inner surfaces capable of resisting continuous temperatures of 150°C. It is prohibited to use plastic or internally corrugated pipes. It is prohibited to position sections with a downward slope.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 7 – ROOM TEMPERATURE THERMOSTAT / CHRONOTHERMOSTAT (optional) Your appliance is already fitted, through the control panel, with all the temperature adjustment and programming functions. However, it is possible to connect the appliance to an additional room temperature thermostat or chronothermostat: --->...
Page 25
ATTENTION: Use N.O. (normally open) contacts for the connection to the chronothermostat. ATTENTION: In the event of connections to the chronothermostat Thermorossi shall not be held responsible for the insert not starting up, smoke leaks, breakage of the lighting component. In the event of a programmed cycle on always ensure that the brazier is clean and seated correctly in its lodging.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 8 - CLEANING AND MAINTENANCE 8.1 FOREWORD Before commencing any operation disconnect the appliance from the electric power outlet. Your pellet appliance needs maintenance; it requires a few simple, basic but frequent control and general cleaning operations. This will guarantee safe and regular operation and optimal output at all times.
Page 27
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 EVERY MONTH inspect and clean the vent identified as V1. To access the vent open the door, Figure 2 remove the ash pan and lift the flap L (Figure 8). EVERY MONTH check that the smoke exhaust is free from fly ash deposits, particularly in the initial sections.
Page 28
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Figure 3 Figure 4 Figure 7 Figure 6 Legenda Figura Figure Ispezione Inspection Page 27...
Page 29
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Figure 8 Figure 10 Figure 9 Figure 11 Page 28...
Page 30
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 8.3 AIR FILTER Your appliance is fitted with an air filter; a practical device that prevents the circulation of dust particles that are always present in domestic environments. The filter (show in the image below) is installed in the bottom right part of the appliance.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 9 – SMOKE DISCHARGE TUBE AND VENTILATION OF THE ROOMS 9.1 FOREWORD Due to the frequent accidents caused by poor functioning of flue outlets installed in private dwellings, we have prepared the following paragraph to assist the installer in his inspection of the parts concerned with eliminating the gases produced by combustion.
Page 32
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 9.3.2 FLUE OUTLET / FLUE SYSTEM COMPONENTS Components and accessories of a Every chimney must have minimum number chimney of components as laid down by standard UNI EN 1443 which are also indicated in the...
Page 33
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 9.3.3 CONTROLS PRIOR TO INSTALLING THE APPLIANCE The user must possess a certificate of conformance for the flue outlet (Ministerial Decree 22 January 2008, no. 37). The flue outlet must be built in compliance with UNI 10683.
ATTENTION: The appearance of one of the alarms described below, does not necessarily imply a defect in the product, but simply Thermorossi S.p.A.’s intention to inform the user of the need for corrective actions in order to guarantee maximum safety, greater reliability and high performance of the appliance.
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 12 – INFORMATION FOR THE SKILLED TECHNICIAN 12.1 MAIN COMPONENTS AND THEIR OPERATION SMOKE PRESSURE SWITCH This is a safety switch that stops the screw feeder motor whenever necessary. The main cause for the pressure switch tripping is a blocked flue outlet or smoke exhaust pipe.
Page 37
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 • The appliance door must always remain closed during normal operation. • Do not touch hot outer surfaces, unless with special equipment. • Do not pour the pellets directly into the brazier. • Keep fuel and inflammable materials at a suitable distance.
Page 38
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Page 37...
Page 39
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 PROBLEM POSSIBLE CAUSE SOLUTION ROOM TEMPERATURE THERMOSTAT SET TOO LOW, APPLIANCE OPERATES THE APPLIANCE NEEDS TO RUN FOR MORE HOURS AT A INTERMITTENTLY HIGHER POWER; SET A HIGHER ROOM TEMPERATURE THE APPLIANCE SHOULD OPERATE FOR MORE TIME AND...
Page 42
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Page 41...
Page 43
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 70015932 VALVOLA DI SFIATO 70017117 da m.19193772000000003 *70018103 VETRO *70018102 COPERCHIO FISSO 70016354 GUARNIZIONE COPERCHIO SERBATOIO 70014154F da m. 19193772000000003 PORTA IN GHISA *70018115 70018229 VALVOLA DI SFIATO COPERCHIO RASCHIA TUBI fino m.19193772000000002...
Page 44
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Page 43...
Page 45
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 Thermorossi S.p.A. Via Grumolo, 4 Z.I.- 36011 Arsiero (VI) – ITALY Page 44...
Page 46
INSTALLATION, USE AND MAINTENANCE GUIDE SlimQuadro 9 – info@thermorossi.it Fax 0445.741657 - www.thermorossi.it Page 45...