Advertisement

Quick Links

OWNER'S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
TYPE : WALL MOUNTED
MODELS
VA123HL
NB0
VA123HL
UB0
P/NO : MFL42262814
www.lg.com

Advertisement

Table of Contents
loading

Summary of Contents for LG VA123HL NBO

  • Page 1 OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. TYPE : WALL MOUNTED MODELS VA123HL VA123HL www.lg.com P/NO : MFL42262814...
  • Page 2: Table Of Contents

    Air Conditioner Owner’s Manual TABLE OF CONTENTS FOR YOUR RECORDS A. Safety Precautions ......3 B. Electrical Safety........6 Write the model and serial numbers here: Temporary Use of an Adapter ....6 Model # Temporary Use of an Extension Cord ...6 Serial # Symbols used in this Manual....6 You can find them on a label on the side of each unit.
  • Page 3: Safety Precautions

    Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4 Safety Precautions Indoor/outdoor wiring connections must Safely dispose off the packing materials. Make sure to check that the power cable be secured tightly and the cable should Like screws, nails, batteries, broken plug is not dirty, loose or broken and be routed properly so that there is no things etc after installation or svc and then only insert the plug completely.
  • Page 5 Safety Precautions Do not use the product for special purposes, Do not block the inlet or outlet of air flow. Use a soft cloth to clean. Do not use such as preserving foods, works of art, etc. It harsh detergents, solvents or splashing is a consumer air conditioner, not a precision water etc .
  • Page 6: Electrical Safety

    Electrical Safety Electrical Safety • This appliance must be properly grounded. To minimize the risk of electric shock, you must always plug into a grounded oulet. • Do not cut or remove the grounding prong from the power plug. • Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the house wiring.
  • Page 7: Product Introduction

    Product Introduction Product Introduction Here is a brief introduction of the indoor and outdoor units. Indoor Units Premium type Rational type Air inlet Allergy free filter Plasma filter + Triple filter Plasma filter Air filter Front gr ON/OFF button Air inlet Air filter Front grille Signal receiver...
  • Page 8: Operating Instructions

    Operating Instructions Operating Instructions How to insert the Batteries 1. Remove the battery cover by pulling it according to the arrow direction. 2. Insert new batteries making sure that the (+) and (-) of battery are installed correctly. 3. Reattach the cover by sliding it back into position. NOTE 1.
  • Page 9: Wireless Remote Controller

    Operating Instructions Wireless Remote Controller The controls will look like the following. ON/OFF BUTTON Used to turn off/on the unit. Signal transmitter OPERATION MODE SELECTION BUTTON Used to select the operation mode. ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature. INDOOR FAN SPEED SELECTION BUTTON Used to select fan speed in six steps low, medium-low, medium, medium-high, high and natural wind.
  • Page 10 Operating Instructions The controls will look like the following. Signal transmitter Premium type : - Optional1 ECO EYE BUTTON Used to set and to cancel the timer operation. - Optional2 JET COOL / MOISTURE COOLING BUTTON Used to start or stop the speed cooling and Moisture Cooling.
  • Page 11: Operation Mode

    Operating Instructions Operation Mode ON/OFF Press the ON/OFF BUTTON to turn the unit on. The unit will respond with a beep. Open the cover of the remote controller and press the operation mode button. Each time MODE the button is pressed, the operation mode is shifted in the direction of the arrow. Auto Healthy Heating...
  • Page 12: Auto Changeover Operation (Optional)

    Operating Instructions Auto Changeover Operation (Optional) This operation is basically heating or cooling function of the air MODE conditioner. But during this operation the controller changes the operation mode automatically to keep the temperature within ±2°C with respect to the setting temperature. Auto Operation(Optional) <For Cooling Model>...
  • Page 13: Air Circulation Operation

    During this operation, 'Cooling' lamp lights up. PLASMA Purification Operation(Optional) Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons. This plasma kills and destroys the contaminants completely to provide clean and hygienic air.
  • Page 14: Energy-Saving Cooling Mode (Optional)

    Operating Instructions Energy-Saving Cooling Mode (Optional) Energy-saving cooling mode can save energy in cooling operation, because it can operate efficiently by setting body-adaptation time according to the change of time and temperature and adjusting desired temperature automatically. 1. Press the ON/OFF BUTTON to start the unit. 2.
  • Page 15: Timer Setting

    Operating Instructions Timer Setting Button on the Description Indication on the LCD Display Remote Controller Press the Timer button once to set on the Reserved 'On' (Press the Timer button twice to set the Reserved 'Off') Press the Time Setting buttons until the desired time is set.
  • Page 16: Horizontal Vane Control

    Operating Instructions Horizontal Vane Control The Horizontal Vane can be adjusted by using the remote controller. 1. Press the ON/OFF BUTTON to start the unit. 2. Press the vertical airflow direction button. Each time the button is pressed, the air-flow direction is changed in the direction of the arrow.
  • Page 17: Jet Cool Operation

    Operating Instructions Jet Cool/Heat Operation Jet cool function can be used to cool the room quickly in hot summer. When this function is turned on, the air conditioner runs in cooling operation mode with super high fan speed and 18°C setting temperature for 30 minutes for fast and effective cooling.
  • Page 18: Eco Eye Operation(Optional)

    Operating Instructions Eco Eye Operation (Optional) Eco Eye operation controls airflow by sensing the position of ECO EYE residents. Each time the button is pressed, the mode is shifted in the direction of the arrow. Direct airflow Indirect airflow Cancellation NOTE •...
  • Page 19 Operating Instructions Detecting Range Vertical angle 90° Direct Airflow Indirect Airflow (Side View) Undetectable zone (1.2 m) Area 1 Area 2 Area 3 Area 1 Area 2 Area 3 A person is detected in area 1. A person is detected in area 1. Horizontal angle 120°...
  • Page 20: Forced Operation

    Operating Instructions Forced operation Forced operation is used when the remote controller can't be used. The operation will be started if the ON/OFF button is pressed. If you want to stop the operation, re-press the button. Premium type Rational type ON/OFF ON/OFF button...
  • Page 21: Auto Restart Function

    Maintenance and Service Auto Restart Function This function is useful in the situation of power failure. When power regains after a failure this feature restore the previous operating condition and the air conditioner will run in the same settings. NOTE This feature is enabled by factory default setting, but you can disable it by pressing the ON/OFF button for 6 seconds.
  • Page 22: Maintenance And Service

    Maintenance and Service Maintenance and Service Before performing any maintenance, turn off the main power to the system, disconnect the circuit breaker and unplug the power cord. Indoor Unit Clean the unit with a soft dry cloth. Do not use bleach or abrasives. Never use any of these •...
  • Page 23: Outdoor Unit

    Maintenance and Service Outdoor Unit The heat exchanger coils and panel vents of the outdoor unit should be checked regularly. If clogged with dirt or soot, the heat exchanger and panel vents may be professionally steam cleaned. NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs. Operation Tips! Do not overcool the room.
  • Page 24: Troubleshooting Tips! Save Time And Money

    Maintenance and Service Troubleshooting Tips! Save time and money! The air conditioner may be operating abnormally when: Problem Possible Causes What To Do ■ The air conditioner is • Make sure the air conditioner plug is unplugged. pushed completely into the outlet. ■...
  • Page 25 Av. Sor Juana lnés de la Cruz No. 555 Col. San Lorenzo LG ELECTRONICS MEXICO, S.A. DE C.V. Tlalnepantla, Estado de México C.P. 54033 Sor Juana Ines de la Cruz No. 555, San Lorenzo Tel. 5321 1919 Tlalnepantla Estado de Mexico Teléfono sin costo 01 800 347 1919...

This manual is also suitable for:

Va123hl ubo

Table of Contents