Model UKF8001AXX-200/UKF8001 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401 and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentraion less than or equal to the permissible limit for water
leaving the system, as specified in NSF/ANSI Standards 42, 53, 401 and CSA B483.1.
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate Class I*
Contaminant Reduction
Lead***: @ pH 6.5 / @ pH 8.5
Mercury: @ pH 6.5 / @ pH 8.5
Asbestos
Cysts
Turbidity
Atrazine
Benzene
Carbofuran
Lindane
P-Dichlorobenzene
Tetrachloroethylene
Toxaphene
Atenolol
Endrin
Ethylbenzene
o-Dichlorobenzene
2,4 - D
Carbamazepine
DEET
Linuron
Meprobamate
Metolachor
Trimethoprim
Bisphenol A
Estrone
Nonylphenol
Ibuprofen
Naproxen
Phenytoin
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.78 gpm (2.95 Lpm). Pressure = 60 psig (413.7 kPa).
Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certified under NSF 401 have been deemed as "emerging compounds/incidental contaminants." Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
It is important that operational, maintenance, and filter replacement
requirements be carried out for the product to perform as advertised. Property
damage can occur if all instructions are not followed.
The disposable cartridge must be changed at least every 6 months.
Use replacement filter UKF8001, Part #EDR4RX D1/EDR4RXD1B. 2015
suggested retail price of $49.99 U.S.A./$49.95 Canada. Prices are subject to
change without notice.

PERFORMANCE DATA SHEETS

Water Filtration System
System tested and certified by NSF International against NSF/ANSI
Standard 42, 53, 401 and CSA B483.1 for the reduction of
contaminants specified on the Performance Data Sheet.
Influent Challenge Concentration
2.0 mg/L ± 10%
At least 10,000 particles/mL
Influent Challenge Concentration
0.150 mg/L ± 10%
0.006 mg/L ± 10%
10
to 10
fibers/L
7
8
††
50,000/L min.
11 NTU ± 10%
0.009 mg/L ± 10%
0.015 mg/L ± 10%
0.080 mg/L ± 10%
0.002 mg/L ± 10%
0.225 mg/L ± 10%
0.015 mg/L ± 10%
0.015 mg/L ± 10%
200 ± 20%
0.006 mg/L± 10%
2.1 mg/L ± 10%
1.8 mg/L± 10%
0.210 mg/L ± 10%
1400 ± 20%
1400 ± 20%
140 ± 20%
400 ± 20%
1400 ± 20%
140 ± 20%
2000 ± 20%
140 ± 20%
1400 ± 20%
400 ± 20%
140 ± 20%
200 ± 20%
Maximum Permissable
Product Water Concentration
50% reduction
85% reduction
Maximum Permissable
Product Water Concentration
0.010 mg/L
0.002 mg/L
>99%
>99.95%
0.5 NTU
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.0002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
30 ng/L
0.002 mg/L
0.7 mg/L
0.6 mg/L
0.07 mg/L
200 ng/L
200 ng/L
20 ng/L
60 ng/L
200 ng/L
20 ng/L
300 ng/L
20 ng/L
200 ng/L
60 ng/L
20 ng/L
30 ng/L
The filter monitor system measures the amount of water that passes through the
filter and alerts you when it is time to replace the filter. To learn how to check
the water filter status, see "Using the Controls" or "Water Filtration System" in
the User Instructions or User Guide.
After changing the water filter, flush the water system. See "Water and Ice
Dispensers" or "Water Dispenser" in the User Instructions or User Guide.
These contaminants are not necessarily in your water supply. While testing was
performed under standard laboratory conditions, actual performance may vary.
Average% Reduction
97.6%
98.8%
Average% Reduction
99.3% / 99.3%
95.1% / 95.0%
>99%
99.99%
98.1%
94.4%
96.6%
86.8%
98.8%
99.7%
96.0%
93.8%
>95.9%
96.7%
99.9%
99.9%
97%
>98.6%
>98.5%
>96.8%
94.6%
98.3%
>96.4%
99.4%
>96.7%
>98.9%
92.9%
>96.3%
>94.8%
17