SAS/SATA Features

Provides eight independent phys, each supporting 6Gb/s and 3Gb/s SAS data
transfers per PHY.
Scalable interface that supports up to 128 physical devices through expanders.
Supports SSP to enable communication with other SAS devices.
Supports SMP to communicate topology management information.
Supports single PHY or wide ports consisting of 2, 3, or 4 PHYs within a single
quad port.
Allows addressing of multiple SATA targets through an expander if using SATA 2.0-
compliant hard disk drives.
Single controller multi-pathing (fail-over).

Online Capacity Expansion and RAID Level Migration Rules

Migration must occur to the same or larger capacity configuration.
Migration cannot occur if there is more than one virtual disk in a logical array.
Migration and OCE cannot be done on Spanned Arrays (RAID 10, 50, and 60).
Migrations supported are RAID 1 to RAID 0, RAID 5 to RAID 0, RAID 6
to RAID 0.
With OCE, migrations supported are RAID 0 to RAID 1, RAID 0 to RAID 5, RAID
0 to RAID 6, RAID 1 to RAID 5, RAID 1 to RAID 6, RAID 5 to RAID 6.

Beep Codes

Short beep (1 second on, 1 second off): Array has degraded but no data has
been lost.
Long beep (3 seconds on, 1 second off): Array has failed and data has been lost.
Short beep (1 second on, 3 seconds off): Using hot spare in rebuild; alarm will
continue during rebuild with a different sound at completion.
To disable the alarm, choose Disable Alarm. To enable the alarm, choose Enable Alarm.
To disable the alarm only until the next event or until next power cycle, choose
Silence Alarm.