Smart initialization automatically checks consistency of virtual disks if there are five
or more disks in a RAID 5 array, which optimizes performance by enabling read-
modify-write mode. RAID 5 arrays of only three or four drives use Peer Read mode.
Smart Technology predicts failures of drives and electronic components.
Patrol Read checks drives and maps bad sectors.
Commands are retried at least four times.
Firmware provides best effort to recognize an error and recover if possible.
Failures are logged from controller and drive firmware, and SMART monitor.
Failures are logged in NVRAM, viewable from OS Event Log, Intel
Console 2, CIM, and LEDs.
Multiple cache options allow configuration-specific performance optimization:
— Write-back: Faster because it does not wait for the disk but data will be lost if
— Write-through: Usually slower but ensures data is on the disk.
— Read Ahead: Predicts next read will be sequential and buffers this data into
— Non Read Ahead: Always reads from the drive after determining exact location
— Adaptive Read Ahead: Reads ahead and caches data only if doing
— I/O setting. Determines whether read operations check the cache before reading
Redundancy through:
— Configuration stored in non-volatile RAM and on the drives (COD).
— Hot-swap support.
— Super Cap 2 backup for cache memory.
4
power is lost.
the cache.
of each read.
sequential reads.
from disks.
✧ Cache I/O: Checks cache first, only reads disk if data is not in the cache.
✧ Direct I/O: Reads data directly from disk. (not cache)