Albalá Ingenieros IPA2000C01 Manual

Dvb-asi and dvb-ip automatic change-over switch with ts failure detection functions and seamless switching

Advertisement

Quick Links

IPA2000C01
DVB-ASI AND DVB-IP AUTOMATIC CHANGE-OVER SWITCH WITH TS
FAILURE DETECTION FUNCTIONS AND SEAMLESS SWITCHING
Version 1.0
Albalá Ingenieros, S.A.
10 January 2017 - © Albalá Ingenieros S.A. - All rights reserved
Medea, 4 - 28037 Madrid - Spain

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IPA2000C01 and is the answer not in the manual?

Questions and answers

Summary of Contents for Albalá Ingenieros IPA2000C01

  • Page 1 IPA2000C01 DVB-ASI AND DVB-IP AUTOMATIC CHANGE-OVER SWITCH WITH TS FAILURE DETECTION FUNCTIONS AND SEAMLESS SWITCHING Version 1.0 Albalá Ingenieros, S.A. 10 January 2017 - © Albalá Ingenieros S.A. - All rights reserved Medea, 4 - 28037 Madrid - Spain...
  • Page 2 IPA2000C01...
  • Page 3: Table Of Contents

    4.3. Description of the TS over IP encapsulators/de-encapsulators ........16 4.4. System latencies .......................... 17 4.5. Module remote control and supervision ................20 4.5.1. Details of the IPA2000C01 registers ................21 5. GLOSSARY ........................31 6. REGULATIONS ........................33 7. VERSIONS ......................... 35...
  • Page 4 IPA2000C01...
  • Page 5: Description

    DVB-over-IP streams (IP TX 1 and IP TX 2). Furthermore, if an EOP2000C01 module is installed in the slot immediately to the left of the IPA2000C01 then two auxiliary ASI inputs become available, and if an EOP2000C02 is installed immediately to the right, then two auxiliary ASI outputs become available.
  • Page 6 SNMP management and the ability to record events in a file including date and time information for further analysis. The IPA2000C01 is a TL2000 terminal line module and can be housed in a two rack unit (2 RU) UR2000 mounting frame.
  • Page 7: Features

    - Two DVB-ASI buses on the backplane of the mounting frame coming from an auxiliary module located in the slot immediately to the left of the IPA2000C01. - Two DVB-over-IP receivers (UDP and RTP with and without FEC) connected to two gigabit Ethernet interfaces.
  • Page 8: Block Diagram

    Albalá Ingenieros | Manual IPA2000C01 1.3. Block diagram...
  • Page 9: Specifications

    Albalá Ingenieros | Manual IPA2000C01 2. SPECIFICATIONS DVB-ASI signal input Connector Impedance 75 Ω ± 1 % Return loss >17 dB up to 270 MHz Number of inputs Equalizable cable length: Belden 8281 >300 m Belden 1694A >350 m DVB-ASI signal output...
  • Page 10 Albalá Ingenieros | Manual IPA2000C01 IPA2000C01...
  • Page 11: Installation

    • The IPA2000C01 module and the mounting frame should always be installed, maintained, operated and removed by personnel with sufficient technical qualifications. The equipment should never be placed in damp areas, near splashing liquid, or in explosive or corrosive atmospheres.
  • Page 12: Environmental Considerations

    1 - Remove the blank panel covering the front of the empty slot chosen for installing the IPA2000C01 in the mounting frame. 2 - Insert the IPA2000C01 module into the front of the mounting frame. The edges of the card slide into two plastic guides inside the mounting frame.
  • Page 13: Interconnection

    Albalá Ingenieros | Manual IPA2000C01 3.5. Interconnection The arrangement of the front panel connectors of the IPA2000C01 module is shown in the following figure. Front panel of the IPA2000C01 The IPA2000C01 module provides DVB-ASI Transport Stream input and outputs as well as Ethernet interfaces.
  • Page 14: Electrical Dvb-Asi Video Connections

    All coaxial cable used must be Belden 8281 or similar. This type provides the greatest lengths because it is used to calculate the equalizers in the IPA2000C01. Cables carrying signal between the module and the devices should use single piece construction, avoiding spliced sections with double BNC female or barrel connectors.
  • Page 15: Operation

    Albalá Ingenieros | Manual IPA2000C01 4. OPERATION This section describes the significance of the front panel indicators of the IPA2000C01 module and their remote control and monitoring ability. 4.1. Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration.
  • Page 16: Functional Description

    In order to avoid unnecessary switching, the recovery time after an error condition has been cleared can be programmed. By default this value is two seconds. Also, when an error is detected at the selected input, the IPA2000C01 only switches to a different input if that input is error-free.
  • Page 17: System Latencies

    • Output buffer: The IPA2000C01 includes a buffer at the output whose operation depends on the operation mode of the module: - DVB-T Mode: In this mode the user sets the network delay, equal to the delay that...
  • Page 18 IPA2000C01 to the response time of the frame synchronization error detectors. When the IPA2000C01 operates in this mode the delay fields in the "General" tab of the control software display the delay of the transport streams received with respect to the 1 PPS reference signal. The delay is measured at the input of the output buffer after IP de-encapsulation.
  • Page 19 If the difference in delay between the two signals is unknown, the information provided by the IPA2000C01's control software can be used to determine this value. In order to find the difference in delay the buffer must be set to a sufficiently large...
  • Page 20: Module Remote Control And Supervision

    Albalá Ingenieros | Manual IPA2000C01 4.5. Module remote control and supervision The IPA2000C01 requires remote control for configuration. In order to perform remote configuration and supervision of the module an optional TLE2001C02 model remote communications controller must be installed in the mounting frame.
  • Page 21: Details Of The Ipa2000C01 Registers

    - Supervision of the status of the inputs and outputs. 4.5.1. Details of the IPA2000C01 registers The IPA2000C01 module provides control and status registers that can be read and written by means of specific commands described in the communication control module user manuals.
  • Page 22 Albalá Ingenieros | Manual IPA2000C01 STAT_RESET 0x01 0x20 Allows reseting the statistics measurements 0=No, 1=Yes STAT_MODE 0x01 0x40 Allows selecting the statistics mode 0=1/s, 1=Total IGMP_VERSION 0x01 0x80 Allows selecting the IGMP version. When enabled the module IGMP response uses always version 2, otherwise it uses thes same version that the Query...
  • Page 23 Albalá Ingenieros | Manual IPA2000C01 CH2_SELECTION 0x0D 0x38 Channel 2 input selection 0=ASI 1, 1=ASI 2, 2=IP 1, 3=IP 2, 4=ASI 1 AUX, 5=ASI 2 AUX TS_SYNC_LOSS_EN 0x0F 0x01 Enables loss of synchronization detection (Fist priority parameter 1.1) 0=No, 1=Yes...
  • Page 24 Albalá Ingenieros | Manual IPA2000C01 STR1_AIP_D_ADD_1 0x04 0x0020 0xFF Alternative multicast IP address (3)Alternative multicast IP address (1) STR1_AIP_D_ADD_0 0x05 0x0020 0xFF Alternative multicast IP address (0) STR1_IGM_A_ADD_3 0x06 0x0020 0xFF Alternative source IP address (3) STR1_IGM_A_ADD_2 0x07 0x0020 0xFF...
  • Page 25 Albalá Ingenieros | Manual IPA2000C01 STR2_IGM_A_ADD_2 0x07 0x0040 0xFF Alternative source IP address (2) STR2_IGM_A_ADD_1 0x08 0x0040 0xFF Alternative source IP address (1) STR2_IGM_A_ADD_0 0x09 0x0040 0xFF Alternative source IP address (0) STR2_A_PORT 0x0A 0x0040 0xFFFF Alternative destination port RX_IP_2_SR_MSK...
  • Page 26 Albalá Ingenieros | Manual IPA2000C01 TTL_1 0x04 0x0060 0xFF Time to live TX_IP_1_SR_ADD_3 0x05 0x0060 0xFF Source IP address (3) TX_IP_1_SR_ADD_2 0x06 0x0060 0xFF Source IP address (2) TX_IP_1_SR_ADD_1 0x07 0x0060 0xFF Source IP address (1) TX_IP_1_SR_ADD_0 0x08 0x0060 0xFF...
  • Page 27 Albalá Ingenieros | Manual IPA2000C01 PRECEDENCE_2 0x03 0x0080 0xE0 TOS. Precedence 0=Routine, 1=Priority, 2=Inmediate, 3=Flash, 4=Flash override, 5=Critic/ECP, 6=Internetwork control,7=Network control TTL_2 0x04 0x0080 0xFF Time to live TX_IP_2_SR_ADD_3 0x05 0x0080 0xFF Source IP address (3) TX_IP_2_SR_ADD_2 0x06 0x0080 0xFF...
  • Page 28 Albalá Ingenieros | Manual IPA2000C01 RX_2_FEC_MODE 0x06 0x00B0 0x60 Protocol 0=UDP, 1=RTP no FEC, 2=RTP FEC A (col.), 3=RTP FEC B (row&col.) RX_2_PACKET_SIZE 0x06 0x00B0 0x80 Bytes in TS packets 0=204, 1=188 RX_2_D_PARAM 0x07 0x00B0 0x1F D parameter (FEC mode rows)
  • Page 29 Albalá Ingenieros | Manual IPA2000C01 LINK_1 0x01 0x0B Ethernet conection status 8=10Mbps, 9=100Mbps, 10=1Gbps, ?=No link SYSTEM_1 0x01 0x0C Ethernet conection system 3=Full Duplex, 2=Half Duplex, ?=No link LINK_2 0x02 0x0B Ethernet conection status 8=10Mbps, 9=100Mbps, 10=1Gbps, ?=No link SYSTEM_2...
  • Page 30 Albalá Ingenieros | Manual IPA2000C01 ARP_VALID_1 0x1B 0x01 Valid ARP response (Unicast mode) 1=OK, 0=Fail ICMP_ERROR_1 0x1B 0x02 Destination unreachable (ICMP destination unrechable packets received) 0=OK,1=Fail ARP_VALID_2 0x1B 0x04 Valid ARP response (Unicast mode) 1=OK, 0=Fail ICMP_ERROR_2 0x1B 0x08 Destination unreachable (ICMP destination unrechable packets received)
  • Page 31: Glossary

    Albalá Ingenieros | Manual IPA2000C01 5. GLOSSARY DVB-ASI Asynchronous Serial Interface. An asynchronous serial interface for DVB streams that is one of the principal formats for transmission of MPEG-2 streams over cable. Forward Error Correction. This technique corrects errors at the receiving point produced in a digital transmission channel by including redundant information at the transmission point in the form of error correction codes.
  • Page 32 Albalá Ingenieros | Manual IPA2000C01 IPA2000C01...
  • Page 33: Regulations

    Albalá Ingenieros | Manual IPA2000C01 6. REGULATIONS EN 50083-9 (1998) Interfaces for CATV/SMATV headends and similar professional equipment for DVB/MPEG-2 transport streams. ETSI TR 101 290 V1.2.1 (2001) Digital Video Broadcasting (DVB); Measurement guidelines for DVB systems. IEEE std 802.3...