  • Page 1 CDP8899 Breath Alcohol Tester Operation Manual Read Carefully Before Use Version: CDP 190118188...
  • Page 2 Notification ➢ To ensure the real test result of alcohol concentration of human blood and avoid sensor damaging, please wait 15 minutes to take test after drinking. ➢ Recommend to calibrate the sensor once the tester indicates CAL "0 Days Left". ➢...
  • Page 3 Instructions icon Please know the icons before using this product. ➢ Warning—May cause danger to user or others. ➢ Caution—May cause damage to tester. ➢ Remarks—Notes instructions additional information. ➢ [ ] button on the alcohol tester. Such as [ ] shows power on/off.
  • Page 4 Terms and Definitions 1、 Breath alcohol analyzers Under specified temperature, humidity pressure, instrument which to analyze and measure the ethanol concentration in exhaled deep lung gases. 2、 Breath alcohol concentration The ethanol content in the breath of each liter, for short, BrAC. The measuring unit is: mg/L.
  • Page 5  QUICK GUIDE Switch on/off: long press [ Steps of testing alcohol content: Install the mouthpiece (see picture). Long press [ ] for power on. Click the <test> icon in the touch screen. Preparing of testing, take a deep breath now.
  • Page 6 Input the driver name: input it by virtual keyboard and click <Enter> for confirmation. Input the vehicle No: input it by virtual keyboard and click <Enter> for confirmation. 10. Input the Driver license No. input it by virtual keyboard and click <Enter>for confirmation.
  • Page 7: Table Of Contents

    Table of contents Summary ................8 Main functions and features: ......... 9 Accessories ............... 10 Structures ................11 Power on/off ..............12 Touch screen usage ............12 Preparation before usage ..........13 Alcohol Content Testing ............. 17 Menu Operation ..............22 Data Uploading ..............
  • Page 8: Summary

    1. Summary CDP8899 is an advanced portable Breath Alcohol Tester with up- to-date design in the international field at present. The core component adopts Changeable Electrochemical Sensor module and the tester is in more accuracy, high sensitivity, strong anti- jamming ability and easy calibration. Adopting advanced technology, CDP8899 could do self-regulation of signal gain, ensure the successful calibration.
  • Page 9: Main Functions And Features

    1.1 Main functions and features: ➢ Using fuel cell smart module, high accuracy and reliability ➢ Adopting advanced technology, CDP8899 could do self- regulation of signal gain, ensure the successful calibration. Simplified the calibration process. ➢ 2.8 Inch Touch color display, beautiful and clear.
  • Page 10: Accessories

    (instrument number, time, tester, test result, etc.). 2. Accessories Alcohol tester DC5.5V 1.0A power cords Date wire Mouthpiece User manual Please use accessories and software under CDP approved, otherwise the instrument may be damaged or malfunction, the manufacturer will not guarantee it.
  • Page 11: Structures

    Could buy accessories from local distributor or manufacturer. The accessories should provide good support to the alcohol tester. Other non-original accessories may not be compatible with the alcohol tester. 3. Structures 1 Air inlet 2 Light 3 Charge lamp 4 Display/touch screen 5 Function key ①...
  • Page 12: Power On/Off

    4. Power on/off 1. Long press [ ] to power on or off the tester 2. Under standby mode, if no operation within 180 seconds continuously, the tester will give out sound to remind user to turn off. If you do not want to turn off, please dot the screen or press any keys, otherwise it will turn off automatically.
  • Page 13: Preparation Before Usage

    No water, it will cause malfunction of touch screen in humidity environment or in contact with water. 6. Preparation before usage Recharging batteries Using the charger which provided by manufacturer. Other inapposite charger will cause explosion or damage tester Low battery indication When the tester is with low battery, it will: ⚫...
  • Page 14 Use DC 5.5V adaptor and date line to recharge alcohol tester. Open the charging/communication jack cover at the side. Insert the small terminal of adaptor into recharging jack. Insert the big terminal pin of adaptor into power socket, then the red indication light of tester will be lighted. If the red light of screen off, and green light is on, it means the finish of recharging.
  • Page 15 Mouthpiece installation This tester is equipped with disposable anti-return mouthpiece which meet hygienic conditions. Before each active blow test, the disposable anti-return mouthpiece should be replaced. For rapid screening and passive test, funnel type mouthpiece is available.
  • Page 16 Printer Connecting Modular thermal printers or independent Bluetooth dot-matrix printers optional. Technical data of Bluetooth Thermal Printer: Paper type: thermal printing paper; Paper width: 57mm; Paper roll diameter: ≤25mm. Technical data of Bluetooth Pin Printer: Paper type: Pin type printing paper; Paper width: 57mm;...
  • Page 17: Alcohol Content Testing

    User Setup Before carrying out test, please read "Part 8 Menu operation" carefully and set Measure unit, alarming point, Police ID input and Time and date etc. 7. Alcohol Content Testing ACTIVE TESTING Breath continuity and minimum expiratory volume Alcohol tester starts to collect a breath sample when the breath sample greater than 1L.
  • Page 18 Active Testing Steps 1. Insert disposable anti-return mouthpiece. 2. Press [ ] to power on. 3. Click [Test]. 4. The test person shall take a deep breath during warming 5. When screen showing "Please blow", the test person must blow into the device continuously and evenly until the buzzer "drops"...
  • Page 19 9. Input of vehicle No: From the virtual keyboard to find the characters, and click <Enter>. 10. Input of driver license No.: From the virtual keyboard to find the characters, and click <Enter>. 11. The screen displays <Print?>, if the tester connected with printer, please click <Print>, the result will be printed.
  • Page 20 Passive Testing Steps 1. Insert disposable funnel type mouthpiece. Press [ ] to power on. 3. Click <Test> to next step. 4. Click <Passive>, then the product would take some air sample from person being tested and active analyzed with result saved. 5.
  • Page 21 9. The screen displays <Print?>, if the tester connected with printer, please click <Print>, the result will be printed. RAPID SCREENING In the standby interface, click <Screening> at the left of the screen to enter the Quick Check Test Interface. Install funnel mouthpiece or without mouthpiece, when the screen prompts <...
  • Page 22: Menu Operation

    8. Menu Operation Time Tem. Battery Menu Icon In the standby interface shown on the left, click on the menu icon on the display screen to enter the corresponding menu items. Some menu requires password validation. The initial password is: 000000.
  • Page 23 Delete Records This operation will clear all test records. The tester could save up to 20000 records and upload records to Computer for Back-up management. Make sure you want to clear all test records before executing this operation. Empty records: 1.
  • Page 24 Five optional measuring units: (BrAC)mg/L (BAC)mg/100mL ‰BAC %BAC After the unit is changed, the critical value in the alarm setting is automatically updated according to the conversion relationship between the old and the new units mg/L and mg/100mL are Chinese standard “GB/T 21254- 2017”...
  • Page 25 Change the password and remember the new password you set. If you forget your password, please contact the dealer or system. Password changing: Click under standby interface. Input original password, click <Enter>. From virtual keyboard to input the new password, click icon to delete characters.
  • Page 26 This operation sets the alarm threshold value, when the test results are less than the set alarm threshold value, only the value of the test results is displayed; when the test results are greater than or equal to the set alarm threshold value, in addition to displaying the test results, the instrument will issue buzzer alarm sound prompt and accompanied by vibration warning.
  • Page 27 Print Copies Set up print copies for testing result or records. Method: Click under standby interface. Input the print copies though the virtual Keyboard, from 1 to 3 copies. The default number of printed copies of the instrument is 2 copies.
  • Page 28 Next Calibration After a certain period of using, it needs to recalibrate the tester to avoid inaccuracy. You can check the left days for next calibration. Method: 1. Click under standby interface to check the calibration remaining days. 2. Click <Enter> to calibrate it or <Cancel> to exit. 3.
  • Page 29: Data Uploading

    3. with blue color. If wrong input, please click to delete then input again. 9. Data Uploading The back-up management on computer requires cooperation of software. Uploading steps: 1. Open the cover of charging or communication socket on the right-side, then, connect computer and apparatus by data communication line.
  • Page 30: Troubleshooting Guides

    10. Troubleshooting Guides Trouble Possible cause Solution Unable to Low voltage Charge timely power on Circuit fault Contact Manufacturer/Distributor Inaccurac Expired sensor Contact manufacturer /Distributor to change sensor Beyond normal Do test in allowed working working Tem. condition Long-term non- Calibrate sensor timely calibration Can’t...
  • Page 31: Main Technique Parameter

    11. Main Technique Parameter Model CDP8899 Sensor Type Fuel-Cell (Electrochemical) Sensor Detecting Scope 0~2.000mg/L Warm-up Time <20s Alarming Point Value 0.250 mg/L Accuracy ±0.02mg/l (0-0.400mg/l) ± 8% (0.400-1.000mg/l) ±20% (1.000-2.000mg/l) Battery 3.7V Lithium Battery Rated capacity 2200mAH Charging Time 4 hours Continuous Operating >12 hour normally...
  • Page 32 Professional Police Breathalyzer Manufacturer  High-tech enterprise with R&D, production, sales capacities and own national brand.  Import and Export rights, passed ISO9001:2000 quality management system certification.  products cover Professional police application, commercial application and gift application.