Piping Diagram
Piping diagram for 2MXM50M3V1B9, 2AMXM50M4V1B, 2AMXF50A2V1B
Outdoor unit
Branch pipe
7.9CuT
7.9CuT
Heat exchanger thermistor
9.5CuT
9.5CuT
9.5CuT
4-way valve
ON: heating
High pressure switch
Automatic reset
HPS1
Muffler
9.5CuT
Discharge pipe thermistor
Accumulator
Compressor
PED categories of equipment - High pressure switches: category IV; Compressor: category II; Other art 4§3 equipment.
English
Heat exchanger
Outdoor air temperature thermistor
Branch pipe
6.4CuT
Twin-branched muffler
4.8CuT
4.8CuT
M
Fan motor
Propeller fan
9.5CuT
9.5CuT
Branch pipe
Muffler
9.5CuT
Muffler
Motor-operated valve
EV
A
Filter
6.4CuT
Motor-operated valve
EV
Filter
B
6.4CuT
Thermistor (gas)
9.5CuT
Gas stop valve
Thermistor (gas)
9.5CuT
Gas stop valve
Refrigerant flow
Cooling
Heating
Thermistor (liquid)
Room ·A·
(6.4CuT)
6.4CuT
Liquid stop valve
Thermistor (liquid)
Room ·B·
6.4CuT
(6.4CuT)
Liquid stop valve
Room ·A·
(9.5CuT)
Field piping
Gas
Room ·B·
(12.7CuT)
Field piping
Liquid
18