Fujitsu ASUH15LPAS Installation Manual page 14

Wall-mounted type
Table of Contents

Advertisement

■ Error code on the wired remote controller (option)
Check the error
1.
If an error occurs, an error icon appears on the "Monitor mode screen".
Touch the [Status] on the "Monitor mode screen". The "Status" screen is dis-
played.
2.
Touch the [Error Information] on the "Status" screen. The "Error Information"
screen is displayed. (If there are no errors, the [Error Information] will not be
displayed.)
3.
2-digit numbers correspond to the error code in the table.
Touch the [Next page] (or [Previous page]) to switch to other connected indoor
units.
1.
2.
Status
Fri 10:00AM
Mode
Set Temp.
Fan
Air Flow Direction
Economy
Unoccupied
Status
Menu
Monitor
■ How to check the error memory
When an error occurs, the operation lamp (Green) and the timer lamp (Orange) indicate the
error content by blinking. To check the error memory, follow the procedures below.
1. Stop the operation of the air conditioner, and then disconnect the power supply.
2. Reconnect the power supply.
3. In one of the following two methods, the memorized error is only displayed during the
"3 minutes ST"* state period.
• Start the operation and then press hold [
more.
or
• Press hold [MANUAL AUTO] on the indoor unit for 10 seconds or more.
2 minutes 20 seconds
Turning on the power supply
Starting operation and then;
- Press hold
or
- Press hold [MANUAL AUTO] on the indoor unit for 10 seconds or more.
*: The "3 minutes ST" period lasts 2 minutes and 20 seconds after turning on the power
supply.
■ How to erase the error memory
 Manual erase: Pressing [MANUAL AUTO] on the indoor unit while the "Error memory
display" is being shown. (Short beep emits for about 3 seconds.)
En-14
3.
Error Information
Page 1/ 4
Address
VT
HZ
02-01
1
3
Error Code
Individual
14,15, 41, 44
Anti Freeze
Off
Off
Next
Error
Back
Page
Information
] on the remote controller for 5 seconds or
Error memory display
In case of "No memorized error display",
TEST RUN display will be shown.
[The operation lamp (Green) and the timer
lamp (Orange) blink at the same time.]
[
]
on the remote controller for 5 seconds or more.
Page 1/ 5
Next
Page

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Asuh07lpas

Table of Contents