Menu Structure - ProLights ARTNETNODE5P User Manual

Table of Contents

Advertisement

Available languages

Available languages

3.2 MENU STRUCTURE

MENU
Net #1-4
1
Net #5-8
2
Subnet #1-4
3
Subnet #5-8
4
5
Universe #1
6
Universe #2
7
Universe #3
Universe #4
8
Universe #5
9
Universe #6
10
Universe #7
11
12
Universe #8
13
DMX Output #1
DMX Output #2
14
15
DMX Output #3
DMX Output #4
16
DMX Output #5
17
18
DMX Output #6
ARTNETNODE
ð
0 - 127
ð
0 - 127
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
0 - 15
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
ð
ArtNet Input
DMX #1 Input
DMX #2 Input
Without Input
Sets the Net address
Sets the Net address
Sets the Subnet address
Sets the Subnet address
Sets the Art-Net universe for the corresponding DMX Out port
(only necessary if the DMX port is set to Art-Net)
ArtNet Input:
Input source for each DMX Out port is Art-Net
DMX #1 Input:
Input source for each DMX Out port is DMX In port 1
DMX #2 Input:
Input source for each DMX Out port is DMX In port 2
Without Input:
DMX Out port is turned off
7

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

ArtnetnodeArtnetnode3p

Table of Contents