IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING.
Pilot Orifice
1. The Main Burner must be removed from the Burner Pan
Assembly (See Burner Removal Section). Adjust the Air
Shutter to the correct Primary Air setting as specified in
the manual or on the label plate. To adjust the Primary
Air setting, loosen screw on the side of the Air Shutter
and rotate to the correct opening using a drill bit or tape
measure. Retighten screw.
2. Remove the Main Burner Orifice using a ½" wrench and
replace with the new Conversion Orifice which came with
the Conversion Kit.
Replace the Main Burner. Install the new Pilot Orifice (See
3.
Pilot Conversion) and Hi/Lo valve regulator by following
instructions supplied with the Conversion Kit.
Refer to "Gas Specifications Chart" for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label as
close to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition system.
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss of
life. The qualified service agency is responsible for the proper installation of this kit. The
installation is not proper and complete until the operation of the converted appliance is checked
as specified in the manufacturer's instructions supplied with the kit.
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion.
Gas Conversion Part A MQZCV48
Main Burner
Hi / Lo Regulator
⚠-Warning-
⚠Caution
Air Shutter & Screw
Main Burner Orifice
Brass Nipple
:
Parts List:
 HI/LO Pressure
Regulator Assembly
 Pilot Orifice
 Burner Orifice
 Brass Nipple
 Instructions
 Conversion Kit Label
Pilot Must
Maintain This
Relationship
With Main
Burner.
67