Troubleshooting
Problem
The bucket does not open or close.
Possible Cause
1. The hydraulic coupler(s) are not
completely connected.
2. There is an obstruction in a hydraulic
hose.
3. The auxiliary valve on the traction unit
is not operating correctly.
4. The 4-in-1 bucket hydraulic cylinder(s)
are not operating correctly.
10
Corrective Action
1. Ensure that the couplers are correctly
connected and secured.
2. Find and remove the obstruction.
3. Repair or replace the valve.
4. Repair or replace any non-operational
hydraulic cylinder(s).