22. Maximum lateral length, for standard zones are as indicated
in Table 1, consult Delta Treatment Systems for alternative
zones.
23. Minimum lateral spacing must be 2 feet, except for special
design.
24. Lateral spacing of three feet or more should be used for
slopes of 20% or greater.
25. Install air vent/vacuum breakers at the high end of each drip
zone supply and return manifold. Air vents/vacuum breakers
to be placed in protective enclosure to prevent an
accumulation of substances that could prevent their proper
operation and they must have a grade level access
26. The size of the installation, type of soil, slope, availability of
labor and cost will determine the best installation method.
During installation cover all open pipe ends including drip
lines to avoid getting dirt or debris into the system. Leave
enough length at the beginning and end of each drip line
for connections. It may be more convenient to finish the last
foot or so of the trench by hand. This gives more room for
connections. Beware of bending the drip tubing too tight
during installation. Do not bend tubing at the 24" radius loops
or the pipe may kink, reducing the flow. Use 1/2" flexible PVC
pipe and fittings to loop emitter pipe. The drip line will
elongate at high temperatures, do not store in direct sunlight.
To prevent stress due to contraction always leave tube snaked
from side to side of trench (1' per 100') or when plowing
INITIAL POLICY
:
The manufacturer or the distributor through the dealer shall furnish a two-year initial service policy tothe user. This policy is
included in the original purchase price and shall provide the following:
1.
An inspection/service call every six months, which includes inspection, adjustment, and servicing of the mechanical
and electrical component parts as necessary to ensure proper function.
2.
If any improper operation is observed which cannot be corrected at that time, the user shall be notified immediately in
writing of the conditions and the estimated date of correction.
CONTINUING SERVICE POLICY:
An annually renewable service policy affording the same coverage as the Initial Service Policy is available. Consult your
dealer for pricing information.
PARTS:
Replacement parts or components may be obtained from your local distributor or directly from Delta Treatment Systems.
COMPLAINTS:
In order for Delta Treatment Systems to properly address any complaints we require that you put in writing the date and
nature of the complaint as detailed as possible. This must include the serial number of your system.
Send to: Delta Treatment Systems
9125 Comar Drive
Walker, LA 70785
27. Install schedule 40 PVC for return flush line. Run return
28. To over come the lack of depth to a restrictive horizon and/or
29. Whenever possible, spend time with your customer. Review
DELTA TREATMENT SYSTEMS
FILTER SERVICE POLICY
9
leave slack at supply and return manifold. Connect drip
lines to sub-main and flush manifolds. Flush again. Run the
system before covering and check for leaks.
line back to the filter system. The electric solenoid valve
that operates the flush line is part of the filter system. Install
schedule 40 PVC drip flush line and filter flush line back to
the treatment plant as shown on the drawings.
seasonal water table a clean fill material of loamy sand, sandy
loam or light loam may be used as fill. The fill material shall
consist of a minimum of 70% sand particles equal to or
greater than 0.25 mm. Clay content shall be 20% or less.
Organic matter should be removed prior to placing fill material.
If not the site must be plowed to prevent an organic sealing
layer from forming. Fill material should be applied over the
entire area in a shallow layer (3 inches) and then be tilled into
the natural soil to prevent a textural interface from forming.
When fill is used, the entire area must be covered with sod to
prevent erosion or other erosion control measures taken.
operation instructions. Be sure that the customer has a
manual to keep with them, this may avoid an unnecessary
return visit.

Advertisement

loading

This manual is also suitable for:

811582308115-1/2hp8230-1hp