GENERAL DESCRIPTION OF
OPERATION
1.
Upon power up at panel there is a 2 minute time delay before
the pump starts.
2.
After this time delay, the pump will start and run for a set
period of time, then turn off for another set period of time.
3.
When the pump starts, the filter flush valve will open for a set
period of time then close.
4.
After a set number of pump starts, the field flush valve will
open for a set period of time after the pump starts and after
the filter flush valve closes.
5.
The field flush cycle will repeat itself on each subsequent
pump cycle for the number of fields connected to the system
before resetting.
6.
In a normal cycle, the field flush valve can be opened for
a period of 60 seconds by momentarily pushing the "Field
Flush" toggle switch up then releasing it. This can be re-
peated for additional flushes.
7.
At the end of each pumping cycle, after the pump shuts off,
both the filter flush and field flush valves will open for a set
period of time then close.
DESCRIPTION OF CONTROL FLOATS
1.
Float FS1 is a wide angle float that when up, permits the
pump to run and when down, keeps the pump from running
and pumping dry. Note that by placing the HAND-OFF-AUTO
switch in HAND position, will by-pass all floats and the pump
will pump dry if held in that position long enough. The switch
spring returns to OFF when released. After FS1 activates,
there is a one minute delay before the pump will start if being
called to run before the float activates.
2.
Float FS2 is the override timer reset float and FS3 is the
override timer float. These floats operate together. If the water
level reaches FS3 while in an OFF period, the pump will start
and the OFF period time will change to the setting in block
B02. The run time remains as set in B01. The shorter OFF
time will remain until the water level reaches FS2 after which
the OFF time reverts back to the normal B01 setting.
3.
Float FS4 is the high level alarm float. When the water level
reaches this float, the high level alarm light illuminates con-
tinuously, and the audible alarm sounds continuously. The
audible alarm can be silenced by the silence switch. When
the high level water level recedes, the alarm will stop.
4.
Float FS5 is an optional float that can be installed below FS1
that will cause an alarm at low water level. Low level alarm
operation is identical to the high level alarm operation except
the alarm light will flash and the audible alarm will sound
intermittently.
5.
Floats FS2, FS3, FS4 can be low current, normally open.
FS1 must be of the wide angle type.FS5 can be low current,
normally closed.