Nokia RM-512 Service Manual page 31

Hide thumbs Also See for RM-512:
Table of Contents

Advertisement

RM-512; RM-513; RM-514; RM-515; RM-543
Service Devices and Service Concepts
Issue 2
MJ-219
MJ-219 is meant for component level troubleshooting.
The jig includes an RF interface for GSM and Bluetooth. in addition, it
has the following features:
• Provides mechanical interface with the engine and UI module
• Provides galvanic connection to all needed test pads in module
• Duplicated SIM connector
• Audio components: IHF, MIC
• Connector for control unit
Note:
CA-128RS (RF cable) is used together with MJ-219.
CA-128RS is not a part of the MJ-219 sales package and has to
be ordered separately.
Note:
Please remove the shield frame before audio testing
by Easy Flash II connector.
The following table shows the attenuation values for MJ-219:
Frequency (Hz)
836600000
881600000
897400000
942400000
1747800000
1842800000
1880000000
1950000000
1960000000
2140000000
PCS-1
The PCS-1 power cable (DC) is used with a docking station, a module
jig or a control unit to supply a controlled voltage.
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
Module jig
Loss (dB)
0.3
0.3
0.3
0.3
0.5
0.5
0.5
0.5
0.5
0.5
Power cable
Page 2 –11