4. Establish input of a standard FM signal to the FM module.
5. Signal generator settings shall be as follows:
i
Frequency: 98 MHz
ii Level: - 60 dBm
iii FM deviation: 75 kHz
iv LFGEN frequency: 1 kHZ
Page 4 –50
Figure 86 Phoenix settings
COMPANY CONFIDENTIAL
Copyright © 2009 Nokia. All rights reserved.
RM-512; RM-513; RM-514; RM-515; RM-543
RF Troubleshooting Instructions
Issue 2