Flue Installation; Electrical Installation - Vaillant ecoTEC plus VU 6/5-5 Series Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

7.11

Flue installation

7.11.1 Installing and connecting the air/flue pipe
1.
You can find out which air/flue pipes may be used
by consulting the enclosed set-up instructions for the
air/flue system.
2.
Observe the information on positioning the air/flue ter-
minal.
Condition: Installation in damp rooms
You must connect the product to a room-sealed air/flue
system. The combustion air must not be taken from the
installation site.
Caution.
Risk of poisoning due to escaping flue
gas.
Mineral-oil-based greases can damage the
seals.
Instead of grease, use only water or com-
mercially available soft soap to aid install-
ation.
3.
Install the air/flue pipe using the set-up instructions.
7.11.2 Replacing the connector for the air/flue pipe
as required
1.
Replace the connector for the air/flue pipe as required.
The product-specific standard equipment is listed un-
der Technical data.
2.
Remove the connector for the air/flue pipe.
(→ Page 28)
3.
If required, install the connector for the air/flue pipe,
80/125 mm diameter. (→ Page 28)
7.11.2.1 Removing the connector for the air/flue pipe
2.
1.
Insert a screwdriver into the slot between the test
points.
2.
Press the screwdriver carefully down (1.).
3.
Turn the connector anti-clockwise (2.) as far as it will
go and then remove it by pulling it upwards (3.).
28
3.
1.
7.11.2.2 Installing the connector for the air/flue pipe,
80/125 mm diameter
1.
Remove the connector for the air/flue pipe.
2.
Insert the alternative connector. In doing so, pay atten-
tion to the latching lugs.
3.
Turn the connector clockwise until it clicks into position.
7.12

Electrical installation

Only qualified electricians may carry out the electrical install-
ation.
Danger!
Risk of death from electric shock!
Power supply terminals L and N remain live
even if the on/off button is switched off:
Disconnect the product from the power
supply by switching off all power supplies
at all poles (electrical partition with a con-
tact gap of at least 3 mm, e.g. fuse or cir-
cuit breaker).
Secure against being switched back on
again.
Wait for at least 3 minutes until the capa-
citors have discharged.
Check that there is no voltage.
7.12.1 Opening the electronics box
Open the electronics box as shown in the figure.
7.12.2 Carrying out the wiring
Caution.
Risk of material damage caused by incor-
rect installation.
Mains voltage at incorrect terminals and plug
terminals may destroy the electronics.
Do not connect any mains voltage to the
eBUS terminals (+/-).
Only connect the mains connection cable
to the terminals marked for the purpose.
Installation and maintenance instructions 0020244997_07