Over the range

Advertisement

Available languages

Available languages

B2
USE TOP CABINET TEMPLATE
FOR PREPARATION OF TOP
CABINET
You need to drill holes for the top support screws, a
hole large enough for the power cord to fit through,
and a cutout large enough for the exhaust adaptor.
• Read the instructions on the TOP CABINET
TEMPLATE.
• Tape it underneath the top cabinet.
• Drill the holes, following the instructions on the
TOP CABINET TEMPLATE.
CAUTION
Wear safety goggles when
drilling holes in the cabinet bottom.
B3.
CHECK BLOWER MOTOR
ORIENTATION
The blower fan blade opening should be facing the top
of the microwave. If the fan opening is already facing
the top of the microwave, skip to Step B5. Otherwise,
continue to Step B4 to adjust the motor orientation.
ADAPTING BLOWER FOR
B4.
OUTSIDE VENTILATION
Remove the cover installed on the blower plate
1
(including one screw). Remove and save screws
holding blower plate to the oven.
Blower
Plate
Screws
31-7000092 Rev. 2
Installation Instructions
Cover Plate
Blower Plate
Back of
Oven
Blower Motor Screw
Cover Plate
Slide the blower plate from under its retaining
2
flange and lift it off. Remove the cover plate
installed on the back. Remove and save screws
that hold blower unit to the oven
Retaining
Flange
Carefully pull out the blower unit. The wires
3
will extend far enough to allow you to adjust the
blower unit.
Roll the blower unit 90° so that fan blade openings
4
are facing toward the top of the microwave.
BEFORE: Fan Blade
Openings Facing
Front
Roll
AFTER: Fan
Blade Openings
Facing Up
Blower
Plate
Blower Motor Screws
Cover Plate
17

Advertisement