This module is used to measure and monitor current consumption by utilizing current transformer technology. The module will collect the voltage signal,
convert and process it into a current value and output the current value with RS485 Modbus RTU protocol. If the current exceeds a preset value, the
relay on the module is activated. Uses include building automation and facility management systems where acquiring information on energy usage can
lead to increased efficiency. They can also detect equipment issues and help prevent damage by detecting over-current and/or short-circuit conditions.
Linear dc sensor & over-current protector (3 pages)
Summary of Contents for Infinite L-com SRCN-C711-2
Page 1
AC CURRENT SENSOR & OVER-CURRENT PROTECTOR User Guide for SRCN-C711-2 Product Description This module is used to measure and monitor current consumption by utilizing current transformer technology. The module will collect the voltage signal, convert and process it into a current value and output the current value with RS485 Modbus RTU protocol. If the current exceeds a preset value, the relay on the module is activated.
Technical Parameters 10 28 VDC Working voltage Power consumption < 0.8 W 0 70 °C Working temperature 10% 90% (No condensation) Working humidity 0 10 A Detection range Function menu Select required functions via keys on module MODBUS RTU ...
Mounting Diagram 35mm DIN rail mounting: Mount the sensor module onto the DIN rail (dark black) as shown in the figure. Board Mount Mount the PCB to the enclosure with screws. Mounting hole diameter is 3mm. Notes The module has the function of anti-reverse connection. But it is still necessary to pay attention to the voltage polarity when the power is turned ON to avoid damage to the module.
Function Menu Description Press and hold the SET button for 3 seconds and release it to enter the function menu interface (F01-F09). Press the + and - buttons to switch in between menus. Select the menu and click the SET button to enter the setting state. The display starts flashing. Set the data with + and - keys, long press the SET key to automatically save the data and exit.
Register Description Note: For detailed functions of the below registers, please refer to the function menu description. Register Illustrate 0x00 Current data register, resolution: 1mA 0x01 Relay status register, display the status of relay operation 0x64 ID registers, range: 1 ~ 247 Baud rate 0x65 1200...
Page 6
Data Write Format Function Code Register Address Write Data CRC Check 1 byte 1 byte 2 bytes 2 bytes 2 bytes 1-247 (Decimal) — — Low in front When the data returned by the module is consistent with the data sent, the relay is unlocked. Tips: The ID range in the command is in decimal format, please convert it to Hex (hexadecimal) format when using it.