• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80 °FDB/67 °FWB(26.67 °CDB/19.44 °CWB), and outdoor temperature of 95 °FDB/75 °FWB (35 °CDB/23.9 °CWB).
– Heating: Indoor temperature of 70 °FDB/59 °FWB (21.11 °CDB/15 °CWB), and outdoor temperature of 47 °FDB /43 °FWB (8.33 °CDB/6.11°CWB).
– Pipe length: 24 ft 7 in (7.5 m), Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *: Sound pressure level
– Measured values in manufacturer's anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
A
Cooling
3
CFM (m
/h)
Heating
W
Cooling
dB (A)
Heating
Dimensions
in (mm)
(H × W × D)
Fin pitch
FPI
Rows × Stages
Pipe type
Type (Material)
Fin
Surface treatment
W
Type
Factory charge
lb (g)
Type
3
3
Amount
in
(cm
)
Material
Color
in (mm)
lb (kg)
Liquid
in (mm)
Gas
ft (m)
Cooling
°F (°C)
Heating
in (mm)
Inverter heat pump
208/230 V ~ 60 Hz
23-5/32 × 34-11/16 × 1-7/16
(588 × 881 × 36.4)
2 lb 10 oz (1,200)
FREOL α68SZ
Approximate color of Munsell 10YR 7.5/1.0
24-1/2 × 31-3/32 × 11-11/32
(620 × 790 × 290)
28-1/16 × 37-7/32 × 15-9/16
(713 × 945 × 395)
14 to 115 (-10 to 46)
-4 to 75 (-20 to 24)
Ø1/2 (Ø13.0) [I.D.], Ø5/8 to Ø11/16 (Ø16.0 to Ø16.7) [O.D.]