3 - Alignment instructions
3-1 Microcontroller con figuration : Service mode
To switch the TV set into service mode please see instruction below.
1 - Select pr. number 91
2 - Adjust sharpness to minimum and exit all menu.
3 - Quickly press the key sequence : RED - GREEN - menu
To software version is displayed beside the word Service, e.g. " SERVICE V1.00A ".
To exit SERVICE men u press men u key or Std By key.
3-2 Service mode navigation
Pr Up / D own remote keys
Vol- / + remote keys
0~7 digit keys
Order
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
: cycle through the service items availa ble.
: Decrement / Increment the values within range.
: Toggle bits 0~7 in option byte
Item
PARABOLA
HOR WIDTH
CORNER
HOR.PARAL
V.LINEAR
EW TRAPEZ
S CORRECT
H BOW
VERT SIZE
VERT CENT
RED GAIN
GRN GAIN
BLUE GAIN
RED BIAS
GRN BIAS
HOR CEN
AGC LEVEL
G2-SCREEN
AFT
OPTION
MAX V OL
Default settingh for wp 895
+140
-1100
-80
-1
-2
-12
-15
+100
+145
+3939
+92
+87
+95
+128
+128
98
-
-
-
-
Not used