Toshiba GF630 Instruction Manual page 44

Electromagnetic flowmeter detector
Hide thumbs Also See for GF630:
Table of Contents

Advertisement

 
 
 
Fluid conductivity:
Fluid temperature: 
Ambient temperature: –20 to + 60℃
Storage temperature:
Storage humidity:
Fluid pressure:
Connection flange standard: See Table 9.1 Type Specification Code.
Principal materials
Case
Carbon steel
Lining
FEP (standard for meter sizes 15 to 250mm)
PTFE (standard for meter sizes 300 to 600mm)
Polyurethane (PU) (standard for meter sizes 15 to 400mm)
Electrodes 316L stainless steel (Polyurethane)
Grounding rings None (standard for Polyurethane, FEP)
See Table 9.1 Type Specification Code for optional materials and other related information.
Coating: Corrosion resistant resin coating (std.), pearl-gray colored
Structure: IP67 and NEMA 4X
5 µS/cm minimum
–20 to +100 °C (FEP)
 
–20 to +120 °C (PTFE)
–20 to +60 °C (Polyurethane)
-25 to +65℃
10 to 90%RH (no condensation)
Up to 1MPa (JIS 10K, ANSI class 150,DIN PN 10)
  Up to 1.6MPa (DIN PN 16)
Hastelloy C equivalent (FEP, PTFE)
316 stainless steel (optional for Polyurethane, FEP)
316 stainless steel (standard for PTFE)
−  43  − 
6F8A0882 

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gf632

Table of Contents