Redlion CUB5VR00 Manual

Redlion CUB5VR00 Manual

Miniature electronic 5-digit dc voltmeter
Hide thumbs Also See for CUB5VR00:

Advertisement

Quick Links

MODEL CUB
®
5V - MINIATURE ELECTRONIC 5-DIGIT DC VOLTMETER
U L
C
C
US LISTED
US LISTED
R
IND. CONT. EQ.
E137808
GENERAL DESCRIPTION
The CUB5 provides the user the ultimate in flexibility, from its complete user
programming to the optional setpoint control and communication capability.
The CUB5V accepts a DC Voltage input signal and provides a display in the
desired unit of measure. The meter also features minimum and maximum
display capture, display offset, units indicator, and programmable user input.
The display can be toggled either manually or automatically between the
selected displays.
The CUB5 display has 0.48" (12.2 mm) high digits. The LCD is available in
two versions, reflective and red/green backlight. The backlight version is user
selectable for the desired color and also has variable display intensity.
The capability of the CUB5 can be easily expanded with the addition of
option cards. Setpoint capability is field installable with the addition of the
setpoint output cards. Serial communications capability for RS232 or RS485 is
added with a serial option card.
The CUB5 can be powered from an optional Red Lion Micro-Line/Sensor
Power Supply (MLPS), which attaches directly to the back of a CUB5. The
MLPS is powered from 85 to 250 VAC and provides up to 400 mA to drive the
unit and sensors.
VOLTAGE
The CUB5V is the DC Volt meter. It features 4 voltage input ranges, that are
selected by the user via a programming jumper and software input range
selection. The ranges consist of following: 0 to 200 mV, 2 V, 20 V, 200 V. Users
should select the appropriate voltage range that covers their maximum input.
DIMENSIONS In inches [mm]
SEL
2.95 [74.9]
Note: Recommended minimum clearance (behind the panel) for mounting clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
1.54 [39.1]
RST
0.15 [3.8]
 FOUR SELECTABLE D.C. RANGES
0 to 200 mV, 2 V, 20 V, 200 V
 MINIMUM AND MAXIMUM DISPLAY CAPTURE
 LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING
 0.48" (12.2 mm) HIGH DIGITS
 OPTIONAL SETPOINT OUTPUT CARDS
 OPTIONAL SERIAL COMMUNICATIONS CARDS (RS232 or RS485)
 OPTIONAL USB PROGRAMMING CARD
 OPERATES FROM 9 TO 28 VDC POWER SOURCE
 FRONT PANEL OR CRIMSON PROGRAMMABLE
 DISPLAY COLOR CHANGE CAPABILITY AT SETPOINT OUTPUT
 NEMA 4X/IP65 SEALED FRONT BEZEL
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions that appear
in this document or on equipment must be observed to ensure personal safety
and to prevent damage to either the device or equipment connected to it.
Do not use these products to replace proper safety interlocking. No software-
based device (or any other solid-state device) should ever be designed to be
responsible for the maintenance of personnel safety or consequential equipment
not equipped with safeguards. Red Lion disclaims any responsibility for
damages, either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
CAUTION: Risk of Danger.
Read complete instructions prior to
installationand operation of the unit.
0.13 [3.3]
1.29 [32.8]
1.71
[43.4]
1
Bulletin No. CUB5V-J
Drawing No. LP0645
Released 06/22
CAUTION: Risk of electric shock.
1.29
[32.8]
2.62 [66.6]

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CUB5VR00 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Redlion CUB5VR00

  • Page 1 Bulletin No. CUB5V-J Drawing No. LP0645 Released 06/22 MODEL CUB ® 5V - MINIATURE ELECTRONIC 5-DIGIT DC VOLTMETER  FOUR SELECTABLE D.C. RANGES 0 to 200 mV, 2 V, 20 V, 200 V  MINIMUM AND MAXIMUM DISPLAY CAPTURE  LCD, REFLECTIVE OR RED/GREEN LED BACKLIGHTING ...
  • Page 2: Specifications

    INPUT CURRENT 13. ENVIRONMENTAL CONDITIONS: @ 9 VDC MODEL DISPLAY COLOR @ 9 VDC WITH Operating Temperature Range for CUB5VR00: -35 to 75°C WITHOUT CUB5RLY0 CUB5RLY0 Operating Temperature Range for CUB5VB00 depends on display color and intensity level as per below:...
  • Page 3: Installation Environment

    ptional ardS ADDING OPTION CARDS : 0.7 V @ 100 mA DS ON : 30 VDC The CUB5 meters can be fitted with optional output cards and/or serial DS MAX Offstate Leakage Current: 0.5 mA max. communications cards. The details for the plug-in cards can be reviewed in the specification section below.
  • Page 4: W Iring The M Eter

    3. Never run Signal or Control cables in the same conduit or raceway with AC Visit RLC’s web site at http://www.redlion.net/emi for more information on power lines, conductors, feeding motors, solenoids, SCR controls, and EMI guidelines, Safety and CE issues as they relate to Red Lion Controls heaters, etc.
  • Page 5: Input Wiring

    4.3 INPUT WIRING Voltage Signal CAUTION: Power input common is NOT isolated from user and input (self powered) commons. In order to preserve the safety of the meter application, the power input common must be suitably isolated from hazardous live earth referenced voltage;...
  • Page 6: Programming Menu

    5.0 r evieWinG the ront uttonS and iSplay BUTTON DISPLAY MODE OPERATION ENTERING PROGRAM MODE PROGRAMMING MODE OPERATION Index display through enabled values Press and hold for 2 seconds to activate Store selected parameter and index to next parameter Advances through the program menu Resets values (MIN/MAX) or outputs Increments selected parameter value or selection OPERATING MODE DISPLAY DESIGNATORS...
  • Page 7: Parameter Menu

    6.1 Module 1 - S iGnal nput araMeterS 1-INP PARAMETER MENU 1-INP rANGE dECPt OFSEt FILtr INP 1 dSP 1 INP 2 dSP 2 USrIN U-ASN bANd StYLE Input Display Display Filter Input Value Display Value Input Value Display Value User Input User Input Filter...
  • Page 8 USER INPUT FUNCTION DISPLAY MODE DESCRIPTION Serial transmit of the active parameters  USrIN Print Request selected in the Print Options menu Print (Module 5).  Same as Print Request followed by a Print and Reset P-r5t momentary reset of the assigned value(s). DISPLAY MODE DESCRIPTION...
  • Page 9 6.3 Module 3 - d iSplay and ront anel utton araMeterS 3-dSP PARAMETER MENU 3-dSP Backlight Unit Only dSP-t ZErO ScroL UNItS COLOr d-LEV CodE Display Front Panel Front Panel Zero Display Display Units Display Display Programming Update Time Display Reset Enable Scroll Indicator...
  • Page 10 6.4 Module 4 - S etpoint utput araMeterS 4-SPt PARAMETER MENU 4-SPt Backlight Unit Only SPSEL Act-n SPt-n HYS-n tON-n tOF-n rSt-n rEn-n Stb-n ChC-n Setpoint Setpoint Setpoint Hysteresis On Time Off Time Output Reset Output Reset Standby Change Display Select Action Value...
  • Page 11 Refer to the CUB5USB bulletin for details on the CUB5 USB programming and programming requirements. RED LION CONTROLS TECHNICAL SUPPORT If for any reason you have trouble operating, connecting, or simply have questions concerning your new product, contact Red Lion’s technical support. Support: support.redlion.net Inside US: +1 (877) 432-9908 Red Lion Controls, Inc. Website: www.redlion.net...
  • Page 12 cuB5v proGraMMinG QuicK overvieW...

This manual is also suitable for:

Cub5vCub5vb00

Table of Contents