Download Print this page
Redlion CUB 5V Series Installation Manual

Redlion CUB 5V Series Installation Manual

Miniature electronic 5-digit dc voltmeter
Hide thumbs Also See for CUB 5V Series:

Advertisement

Quick Links

Model CUB
Installation Guide
U L
C
C
US LISTED
US LISTED
R
IND. CONT. EQ.
E137808
See the Red Lion website at www.redlion.net for full user manual.
SAFETY SUMMARY
All safety related regulations, local codes as well as instructions
that appear in this document or on equipment must be observed
to ensure personal safety and to prevent damage to either the
device or equipment connected to it.
Do not use these products to replace proper safety interlocking.
No software-based device (or any other solid-state device) should
ever be designed to be responsible for the maintenance of
personnel safety or consequential equipment not equipped with
safeguards. Red Lion disclaims any responsibility for damages,
either direct or consequential, that result from the use of this
equipment in a manner not consistent with these specifications.
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
ORDERING INFORMATION
PART NUMBER DESCRIPTION
CUB5VR00
DC Volt Meter with reflective display
CUB5VB00
DC Volt Meter with backlight display
CUB5RLY0
Single Relay Option Card
CUB5SNK0
Dual Sinking Open Collector Output card
CUB5COM1
RS485 Serial Communications Card
CUB5COM2
RS232 Serial Communications Card
CUB5USB0
USB Programming Card
DIMENSIONS In inches (mm)
SEL
2.95 (74.9)
5V - Miniature Electronic
®
CAUTION: Risk of electric shock.
Optional
1.54 (39.1)
RST
.15 (3.8)
5-Digit DC Voltmeter
SPECIFICATIONS
1. POWER: Input voltage range is +9 to +28 VDC with short
circuit and input polarity protection. Must use an RLC model
MLPS or an NEC Class 2 or Limited Power Source (LPS) rated
power supply.
MODEL NO.
CUB5VR00
CUB5VB00
CUB5VB00
Green (max intensity)
2. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5VR00: Reflective LCD with full viewing angle
CUB5VB00: Transmissive LCD with selectable red or green
LED backlight, viewing angle optimized. Display color change
capability with output state when using an output module.
3. INPUT RANGES: Jumper Selectable
D.C. Voltages: 200 mV, 2 V, 20 V, 200 V
4. RESPONSE TIME:
Display: 500 msec min.
Output: 800 msec max (with input filter setting of 0)
5. USER INPUT (USR): Programmable input. Connect terminal
TYPE
to common (USR COMM) to activate function. Internal 10KΩ
pull-up resistor to +9 to 28 VDC.
6. ENVIRONMENTAL CONDITIONS:
CUB5
Operating Temperature Range for CUB5VR00: -35 to 75°C
Plug-in
Cards
Note: Recommended minimum clearance (behind the panel) for mounting
.13 (3.3)
clip installation is 2.15" (54.6) H x 3.00" (76.2) W.
1.29 (32.8)
1.71
(43.4)
1
INPUT CURRENT
@ 9 VDC
DISPLAY COLOR
WITHOUT
CUB5RLY0
---
10 mA
Red (max intensity)
85 mA
95 mA
+.025
2.68
-.000
+8
(68
)
-0
Install CUB5V- A
Drawing No. LP1137
Effective 07/2020
INPUT
CURRENT @
9 VDC WITH
CUB5RLY0
40 mA
115 mA
125 mA
+.024
1.30
-.000
+6
(33
)
-0

Advertisement

loading
Need help?

Need help?

Do you have a question about the CUB 5V Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Redlion CUB 5V Series

  • Page 1 IND. CONT. EQ. E137808 SPECIFICATIONS See the Red Lion website at www.redlion.net for full user manual. 1. POWER: Input voltage range is +9 to +28 VDC with short circuit and input polarity protection. Must use an RLC model SAFETY SUMMARY...
  • Page 2 Drawing No. LP1137 Effective 07 2020 Operating Temperature Range for CUB5VB00 depends on The panel latch should be engaged in the farthest forward slot display color and intensity level as per below: possible. To achieve a proper seal, tighten the latch screws evenly until the unit is snug in the panel (Torque to approx.
  • Page 3 Effective 07 2020 Drawing No. LP1137 WIRING THE METER User Input Wiring Wiring Overview Electrical connections are made via screw-clamp terminals Sinking Logic located on the back of the meter. All conductors should conform USR COMM Connect external switching device between the to the meter’s voltage and current ratings.
  • Page 4 Red Inc. All other company and product names are trademarks of Lion’s technical support. their respective owners. Support: support.redlion.net Website: www.redlion.net Inside US: +1 (877) 432-9908 Outside US: +1 (717) 767-6511 LIMITED WARRANTY (a) Red Lion Controls Inc.

This manual is also suitable for:

Cub5vr00Cub5vb00