Advertisement

Quick Links

SANITATION
BTU /
Model
Burner(s)
Burner
NGHP-2
2
NGHP-4
4
25,000
NGHP-6
6
*Overall dimensions include the gas regulator located on the back of the unit
BEFORE OPERATING ANY EQUIPMENT, READ AND FAMILIARIZE YOURSELF WITH THESE USE AND SAFETY INSTRUCTIONS
Congratulations on your purchase of this SPECTRUM
are sure to experience years of reliable operation from this equipment. To ensure best results, it is important that you read and follow the
instructions in this manual carefully. It is important to keep these instructions in a safe place for future reference.
GAS COUNTERTOP EQUIPMENT,
NATURAL / LP
Operating Instruction Manual
NGHP-2
Total
Pressure
Orifice
BTU/HR
IN. W.C
Size
50,000
Nat #43
100,000
4" / 10"
LP #53
150,000
hot plate. When used as intended, and with proper care and maintenance, you
TM
HOT PLATES
Overall Dimensions
Length
Depth*
Height
12"
(304.8mm)
24"
29-1/8"
15"
(609.6mm)
(739.1mm)
(381mm)
36"
(914.4mm)
NGHP-4
NGHP-6
Grate Surface
Weight
Length
Depth
12"
50 lbs
(304.8mm)
(24.5 kgs)
24"
24"
88 lbs
(609.6mm)
(609.6mm)
(43.5 kgs)
36"
126 lbs
(914.4mm)
(62 kgs)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Spectrum NGHP-2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Winco Spectrum NGHP-2

  • Page 1: Specifications

    GAS COUNTERTOP EQUIPMENT, HOT PLATES NATURAL / LP Operating Instruction Manual NGHP-2 NGHP-4 NGHP-6 SANITATION Overall Dimensions Grate Surface BTU / Total Pressure Orifice Model Burner(s) Weight Burner BTU/HR IN. W.C Size Length Depth* Height Length Depth 12” 12" 50 lbs NGHP-2 50,000 (304.8mm)
  • Page 2: Warnings

    GAS HOT PLATE Important For Future Reference Please complete this information and retain this manual for the life of the equipment. For Warranty Service and/or parts, this information is required. Model Number Serial Number Date Purchased WARNING: For your safety, do not store or use gasoline AVERTISSEMENT: Pour votre sécurité, ne pas stocker ni or other flammable vapors or liquids in the vicinity of utiliser d'essence ou d'autres vapeurs ou liquides...
  • Page 3: Table Of Contents

    If you have questions concerning the installation, operation, maintenance or LOCATION OF DATA PLATE service of this product, please contact WINCO®. The data plate is located on the rear or side panel. IMMEDIATELY INSPECT FOR SHIPPING DAMAGE All containers should be examined for damage before and during unloading.
  • Page 4: Safety Precautions

    Safety Precautions DANGER: This symbol warns of imminent hazard which Risque: Ce symbole avertit du danger imminent qui peut will result in serious injury or death. entraîner des blessures graves ou la mort. WARNING: This symbol refers to a potential hazard AVERTISSEMENT: Ce symbole indique un danger potentiel or unsafe practice, which could result in serious injury ou une pratique dangereuse, qui peut entraîner des...
  • Page 5: Installation

    Installation These instructions should be followed at all times. Failure to follow these Leg Installation: instructions could result in injury to yourself and others. The Hot Plate must not be operated without the legs attached. INSTALLATION CODES AND STANDARDS 1. Install adjustable legs by screwing leg post into recess nut at each corner The Hot Plate Range must be installed in accordance with: of unit frame.
  • Page 6: Conversion

    Gas Connection: Combustible clearances: 1. The data plate on rear or side of the Hot Plate indicates the type of gas the unit is equipped to burn. DO NOT connect to any other gas type. 6" sides (152 mm) 6" rear (152 mm) 4"...
  • Page 7: Lighting Pilot

    Note Conversion PLEASE CHECK LEAKAGE BEFORE RE-INSTALLING CONTROL PANEL. 2. Unscrew bolts and pilot valve, then remove the manifold (Fig.4). Lighting Instructions LIGHTING PILOT The pilot light on the appliance has been set at the factory. A screwdriver may be required for the first lighting to adjust the flame for your elevation. Fig.4 Pilot valve 3.
  • Page 8: Safety

    Do not use hose or pressure wash to clean. water for 15 to 20 minutes. Then either brush with a wire brush or clean If the machine is damaged, it must be repaired by a WINCO Approved gas ports with a sharp-pointed metal instrument to ensure open ports.
  • Page 9: Troubleshooting

    Parts protected by the manufacturer or its agent are not to be adjusted by the installer unless the installer is an authorized service agent. If you have any questions or problems DO NOT send unit to WINCO® without first contacting our customer service department.
  • Page 10: Exploded View

    Exploded Views MODEL SHOWN: NGHP-SERIES 24" unit shown Internal External...
  • Page 11: Spare Parts List

    Spare Parts List MODELS: NGHP-2 / NGHP-4 / NGHP-6 GAS HOT PLATES NGHP-2 NGHP-4 NGHP-6 DESCRIPTION PART # PART # PART # Grate NGHP-P3 NGHP-P3 NGHP-P3 Burner NGHP-P4 NGHP-P4 NGHP-P4 Long Pilot Tube NGHP-P5 NGHP-P5 NGHP-P5 Short Pilot Tube NGHP-P6 NGHP-P6 NGHP-P6 Manual Gas Valve A18...
  • Page 12: Limited Warranty

    This warranty is given only to the first purchaser from a retail dealer. No 4. Use of generic or after-market parts. warranty is given to subsequent transferees. 5. Repairs made by anyone other than a WINCO® designated service provider. Warranty does not cover product failures caused by: failure to maintain, 6. Lubrication.

This manual is also suitable for:

Spectrum nghp-4Spectrum nghp-6