2021 年 7 月 29 日 株式会社神戸清光 【BLK360 の FW v2.1.0 がリリースされ、BLK360 と PC のケーブル接続に関する件】 v2.1.0 にアップグレードすることにより USB Type-C 端子で PC とケーブル接続できるように なりますが、単純に FW をアップグレードすれば良いというわけではありませんので以下、ご 注意ください。 ●シリアルナンバー 3507273 以降の BLK360 こちらは既に USB 端子が利用可能な状態で出荷されていますので、FW を最新の v2.1.0 に更新すれば PC とケーブル接続できます。 これには ・BLK360 シリアル#3507273 以降...
Page 2
Leica Geosystems Release Notes Product Leica BLK360 Imaging Laser Scanner Date 1st July 2021 From Björn Beutelspacher Leica BLK360 Imaging Laser Scanner – Firmware v2.1.0 Leica Geosystems AG Heinrich-Wild-Strasse CH-9435 Heerbrugg Schweiz www.leica-geosystems.com...
Page 3
Please note that Leica Cyclone FIELD 360 versions before v2.4 can show data download issues when used with BLK360 firmware v2.0.0. It is strongly recommended to update Leica Cyclone FIELD 360 to the latest version v3.1.0 when being connected to BLK360 firmware v2.0.1!
Page 4
Features and firmware improvements directly available for the user after the firmware update. 1. Data transfer over cable To have a faster and more robust data transfer of scans from the Leica BLK360 to a computing device v2.1.0 supports the data transfer over LAN cable.
Page 5
BLK360, the LED will go into red error state, indicating that this setup is currently not supported. When the Leica BLK360 is in red error state, it is as well not possible to connect to it using the Leica Cyclone Field360 app.
Page 6
The 2nd option is to connect the BLK360 to a network, e.g. a router. This option requires a given network structure. Furthermore the used router with BLK360 must be in the same subnetwork as the computing device to ensure Leica Cyclone Data Manager or Leica Cyclone Register 360 can connect to the device.
Page 7
Other communication for BLK360 to PC, for example via a USB-C to USB-C cable, is not supported. Also charging the Leica BLK360 battery inside the device via the USB-C plug is not supported and can damage the Leica BLK360.
Page 8
In rare cases the sensor shuts down unexpectedly this will be indicated by a warning state (orange LED ring) at the next start of the device. A press on the power button will reset the warning state and the Leica BLK360 will again be fully operational.
Cyclone Field 360 will show an error message when trying to start a scan although the Leica BLK360 is in warning state. A restart of the sensor as stated in the error message is not required. As written above, a simple press on the power button solves the issue and the scan can be started.