Fundamental Risks - GCE druva PTLH0FT Instructions For Use Manual

Point of use regulator
Table of Contents

Advertisement

Available languages

Available languages

Noise generation
In some cases, the unfavorable interaction of certain infl uencing variables, such as fl ow rate and pressure
range, but also the type of gas itself, can lead to noise generation.
In such cases, please contact the manufacturer.

2.2. FUNDAMENTAL RISKS

The following section addresses the residual risks that may arise, even if the system is used properly.
Observance of the safety information included below and in other sections of these instructions is mandatory
in order to reduce the risk of injury and property damage and to avoid dangerous situations.
DANGER!
Gases can be life threatening!
Gases can supersede the oxygen in air. This can result in death by asphyxiation. Oxygen produces a
strongly oxidizing eff ect.
THEREFORE:
Suffi cient ventilation is absolutely essential.
Installation only through certifi ed company.
Observe ATEX directive.
ATTENTION!
Risk of injury from environment!
There can be malfunctions on component due to condensation and/ or icing.
THEREFORE:
Observe suitable temperatures.
Protect component from liquids from outside
Protect component from dust from outside
Protect component from weather conditions
Grounding has to be mounted properly
WARNING!
Risk of injury from using oil and grease!
Oil and grease must never be used in gas regulating systems. Oil and grease are highly infl ammatory and
can react violently to certain pressurized gases.
THEREFORE:
Never use oil and grease
WARNING!
Risk of injury from residual energy stored in the system!
If handled incorrectly, pressurized components can move uncontrollably and cause severe injury. If handled
incorrectly or defective, pressurized components can leak gas under high pressure and cause severe or
even fatal injuries.
BEFORE STARTING WORK WITH THESE COMPONENTS:
Installation only through certifi ed company.
Always wear protective goggles when working.
Always wear ear protection.
Make sure the equipment is depressurized. Also make sure the residual energy is discharged.
Always ensure that gas cannot leak unintentionally.
Make sure that defective components that are pressurized during operation are immediately replaced by
trained staff .
7/44
EN

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Ptlheft

Table of Contents