GCE druva PTLH0FT Instructions For Use Manual page 19

Point of use regulator
Table of Contents

Advertisement

Available languages

Available languages

Description
Reason
Increase of
Leakage in
outlet pressure
pressure regu-
& relief valve
lator seat
opens
Slight increase
Inlet pressure
of outlet pres-
drop
sure & relief
valve does not
open
Slight increase
Diff erence
of outlet pres-
between fl ow
sure
pressure (with
gas fl ow) and
Zero Pressure
(without gas
fl ow)
Slight drop of
Diff erence
outlet pressure
between fl ow
pressure (with
gas fl ow) and
Zero Pressure
(without gas
fl ow)
Heavy drop of
Required
outlet pressure
fl ow to high
for pressure
regulator
Heavy drop of
Leakage in
outlet pressure
process gas
tubing
Outlet Pres-
Wrong set-
sure to high
tings for pres-
sure regulator
Outlet pres-
Pollution or
sure increase
damage of
immediately
pressure
all the way to
regulator seat
the stop or
"Creap"
outlet pressure
increases and
gets slowly
higher than set
value and relief
valve opens
Solution
Valve
Repair by
manufacturer
No failure, nor-
mal operating
state
No failure, nor-
mal operating
state
No failure, nor-
mal operating
state
Choose new
pressure
regulator for re-
quired pressure
and fl ow
Check process
gas tubing
Adjust pressure
regulator set-
tings, readjust
pressure
regulator, main-
tenance
Repair by
manufacturer
19/44
Cylinder
Point of use
Regulator
regulator
Gas
Supply
Panel
EN