Safety Devices - Fujitsu ASYG07KETF Design & Technical Manual

Wall mounted type
Table of Contents

Advertisement

11. Safety devices

Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Type of protection
Circuit protection
Current fuse (Main PCB)
Fan motor
Terminal protection
protection
program
Terminal protection
Compressor
program
protection
(Discharge temp.)
Protection form
Activate
Reset
Activate
Reset
Protection form
Activate
Reset
Activate
Reset
- 68 -
Model
AOYG07KETA
250 V, 20 A
250 V, 5 A
85—122 °C
Fan motor stop
77—114 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
Model
AOYG12KETA
250 V, 20 A
250 V, 5 A
85—122 °C
Fan motor stop
77—114 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
AOYG09KETA
AOYG14KETA
11. Safety devices