518674-YIM-C-0610
ZF078-150 Hi Static Motor - With Powered Convenience Outlet
Compressors
(each)
Size
Volt
(Tons)
RLA LRA
MCC
208
9.3
68
14.5
230
9.3
68
14.5
078
(6.5)
460
4.9
34
7.7
575
3.8
28
6
208
11.9
88
18.5
230
11.9
88
18.5
090
(7.5)
460
5.2
44
8.1
575
4.8
36
7.5
208
12.2
88
19
230
12.2
88
19
102
(8.5)
460
5.8
44
9
575
4.4
36
5.5
26
OD Fan
Supply
Pwr
Pwr
Motors
Blower
Exh
Conv
(each)
Motor
Motor
Outlet
FLA
FLA
FLA
FLA
1.5
6.8
5.5
10
1.5
6.8
5.5
10
0.8
3.4
2.2
0.6
2.7
1.8
3.5
9.6
5.5
10
3.5
9.6
5.5
10
1.6
4.8
2.2
1.3
3.9
1.8
3.5
9.6
5.5
10
3.5
9.6
5.5
10
1.6
4.8
2.2
1.3
3.9
1.8
Electric Heat Option
Model
kW
Stages Amps
None
-
-
E09
6.8
1
18.9
E18
13.5
2
37.5
E24
18
2
50.0
E36
25.5
2
70.8
None
-
-
E09
9
1
22.6
E18
18
2
45.2
E24
24
2
60.2
E36
34
2
85.3
None
-
-
E09
9
1
11.3
5
E18
18
2
22.6
E24
24
2
30.1
E36
34
2
42.7
None
-
-
E09
9
1
4
E18
18
2
18.1
E24
24
2
24.1
E36
34
2
34.1
None
-
-
E09
6.8
1
18.9
E18
13.5
2
37.5
E24
18
2
50.0
E36
25.5
2
70.8
None
-
-
E09
9
1
22.6
E18
18
2
45.2
E24
24
2
60.2
E36
34
2
85.3
None
-
-
E09
9
1
11.3
5
E18
18
2
22.6
E24
24
2
30.1
E36
34
2
42.7
None
-
-
E09
9
1
4
E18
18
2
18.1
E24
24
2
24.1
E36
34
2
34.1
None
-
-
E09
6.8
1
18.9
E18
13.5
2
37.5
E24
18
2
50.0
E36
25.5
2
70.8
None
-
-
E09
9
1
22.6
E18
18
2
45.2
E24
24
2
60.2
E36
34
2
85.3
None
-
-
E09
9
1
11.3
5
E18
18
2
22.6
E24
24
2
30.1
E36
34
2
42.7
None
-
-
E09
9
1
4
E18
18
2
18.1
E24
24
2
24.1
E36
34
2
34.1
1
MCA
1
MCA
w/Pwr
(Amps)
Exh
(Amps)
-
40.9
46.4
44.6
51.5
67.8
74.7
83.5
90.3
109.5
116.4
-
40.9
46.4
48.1
54.9
75.1
82
93.2
100
123.2
130.1
-
21.1
23.3
24
26.8
37.6
40.3
46.6
49.3
61.6
64.4
-
16.5
18.3
9.0
19.2
21.5
30
32.3
37.2
39.5
49.3
51.5
-
53.4
58.9
53.4
58.9
71.3
78.2
87
93.8
113
119.9
-
53.4
58.9
53.4
58.9
78.6
85.5
96.7
103.5
126.7
133.6
-
24.7
26.9
25.8
28.5
39.3
42.1
48.3
51.1
63.4
66.1
-
21.3
23.1
9.0
21.3
23.1
31.5
33.8
38.7
41
50.8
53
-
54.1
59.6
54.1
59.6
71.3
78.2
87
93.8
113
119.9
-
54.1
59.6
54.1
59.6
78.6
85.5
96.7
103.5
126.7
133.6
-
26.1
28.3
26.1
28.5
39.3
42.1
48.3
51.1
63.4
66.1
-
20.4
22.2
9.0
20.7
23
31.5
33.8
38.7
41
50.8
53
Johnson Controls Unitary Products
2
Max Fuse
/
2
Max Fuse
/
3
Breaker
3
Breaker
Size w/ Pwr
Size
Exh
(Amps)
(Amps)
50
50
50
60
70
80
90
100
110
125
50
50
50
60
80
90
100
100
125
150
25
25
25
30
40
45
50
50
70
70
20
20
20
25
30
35
40
40
50
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
25
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60
60
70
60
70
80
80
90
100
125
125
60
70
60
70
80
90
100
110
150
150
30
30
30
30
40
45
50
60
70
70
25
25
25
25
35
35
40
45
60
60