Pictograms And Symbols; Safety Instructions - Beko BM33U Instructions For Installation And Operation Manual

Condensate drain
Table of Contents

Advertisement

Pictograms and symbols

Pos: 1 /Beko Technische Dokumentation/Überschriften/1/Piktogramme und Symbole @ 1\mod_1290773595840_2901.docx @ 20524 @ 1 @ 1
Pictograms and symbols
1
Pos: 2 /Beko Technische Dokumentation/Piktogramme/Anleitung beachten blau @ 0\mod_1213268300255_2901.docx @ 8336 @ @ 1
Observe the installation and operating instructions
Pos: 3 /Beko Technische Dokumentation/Piktogramme/Anleitung beachten s/w Typenschild @ 1\mod_1290772180142_2901.docx @ 20491 @ @ 1
Observe the installation and operating instructions (on the type plate)
Pos: 4 /Beko Technische Dokumentation/Piktogramme/Gefahr Warnung Vorsicht s/w @ 0\mod_1213265685174_2901.docx @ 8260 @ @ 1
General danger symbol (danger, warning, caution)
Pos: 5 /Beko Technische Dokumentation/Piktogramme/G+W+V Netzspannung s/w @ 0\mod_1213266193701_2901.docx @ 8298 @ @ 1
General danger symbol (danger, warning, caution) for supply voltage and
supply voltage-carrying plant components
Pos: 6 /Beko Technische Dokumentation/Überschriften/1/Sicherheitshinweise @ 0\mod_1183637609261_2901.docx @ 5367 @ 1 @ 1
2

Safety instructions

Pos: 7 /Beko Technische Dokumentation/Globale Texte/Allgemeiner Hinweis BM @ 0\mod_1183615737313_2901.docx @ 4006 @ @ 1
Pos: 8 /Beko Technische Dokumentation/Sicherheit/Hinweis Anleitung BEKO (männl. Name) @ 0\mod_1184147787557_2901.docx @ 5760 @ @ 1
Please check whether or not these instructions correspond to the device type.
Adhere to all advice given in these operating instructions. They include essential information
which must be observed during the installation, operation and maintenance. Therefore it is
imperative for the service technician and the responsible operator / technical staff to read
these operating instructions prior to installation, start-up and maintenance.
The operating instructions must be accessible at any time at the place of application of
the BEKOMAT
In addition to these operating instructions, local or national regulations must be complied with,
if necessary.
Make sure that the BEKOMAT
values indicated on the type plate. Any deviation involves a risk for persons and materials,
and may result in malfunction and service failures.
If you have any queries regarding these installation- and operating instructions, please
contact BEKO TECHNOLOGIES GMBH.
Pos: 9 /Beko Technische Dokumentation/Sicherheit/Gefahr Druckluft @ 0\mod_1184148143854_2901.docx @ 5778 @ @ 1
Danger!
Compressed air!
Risk of serious injury or death through contact with quickly or suddenly escaping
compressed air or through bursting plant components or plant components which
are not secured.
Pos: 10 /Beko Technische Dokumentation/Sicherheit/Maßnahmen Druckluft BM @ 0\mod_1184148284291_2901.docx @ 5814 @ @ 1
Measures:
Do not exceed the maximum operating pressure (see type plate).
Only carry out service measures when the system is pressureless.
Use pressure-resistant installation material only.
The feed pipe must be tubed firmly.
Discharge pipe: short, fixed pressure hose onto pressure-resistant pipe.
Make sure that persons or objects cannot be hit by condensate or escaping compressed air.
Pos: 11 /Beko Technische Dokumentation/Sicherheit/Gefahr Netzspannung 1 s/w @ 0\mod_1184148186948_2901.docx @ 5796 @ @ 1
4
®
33U / 33U CO .
®
33U / 33U CO is operated only within the permissible limit
BEKOMAT® 33U / 33U CO

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bekomat 33u coBekomat 33uBm33uco

Table of Contents