Inspection and maintenance
19
24
18
17
9. Insert new cover O-ring (18)
according to the diagram.
10. C lean the sealing surfaces of the cover.
11. P ut on the cover (17) with the new O-ring
and carefully tighten the four cover screws (16)
crosswise (8 Nm).
12. C lean the sealing surfaces (←)
at the condensate receiver tank (19).
gasket kit)
(