Figure 5-9 - Thermostatic Mixing Valve Element - Gardner Denver AUTO SENTRY EAU99P Operating And Service Manual

Electra-saver stationary base-mounted compressor
Table of Contents

Advertisement

1.
To remove the oil filter, using a 1" socket unthread the oil filter from the housing.
2.
Rotate the filter head (aluminum assembly) to align the channel in the head with the tabs on the
oil filter element..
3.
Lift the threaded part of the filter head until it is seated against the top of the filter head.
4.
With the channel aligned and the threaded portion of the filter head against the top of the filter
head, disassemble the filter element from the filter head.
5.
To install a new oil filter, rotate the threaded portion of the filter head to align the channel.
6.
Align the tabs on the filter element with the channels in the filter head and snap the element into
the filter head.
7.
Press the filter assembly into the filterstat assembly. Using a 1" socket tighten down the oil filter,
until the o-ring seals. Do not overtighten.
8.
Run the unit and check for leaks.
COMPRESSOR OIL COOLER - RADIATOR TYPE (Figure 1-5, page 11 and Figure 1-6, page 12) - The
oil cooler motor and fan is mounted on the oil cooler module; air is exhausted through the oil cooler and
away from the unit. Do not obstruct air flow to and from the oil cooler. Allow a minimum of three (3) feet
clearance around the cooler. Keep both faces of cooler core clean for efficient cooling of compressor oil.
Figure 5-9 – THERMOSTATIC MIXING VALVE ELEMENT
Ducting will be required on air cooled quiet enclosed machines.
13-10-615