COMPRESSOR OIL FILTER (
maintaining a trouble-free compressor, since it removes dirt and abrasives from the circulated oil. The oil
filter relief valve is integrated into the replaceable oil filter element.
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
Improper oil filter maintenance will cause damage to equipment. Replace filter
element every 1000 hours of operation. More frequent replacement could be
required depending on operating conditions. A filter element left in service too
long may damage equipment.
Use the following procedure to replace the filter. Do not disturb the piping:
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
, page 43) - This patented design screw-i oil filter is a vital part in
Figure 5-3
C
A
U
T
C
A
U
T
C
A
U
T
13-10-615
I
O
N
I
O
N
I
O
N
Page 52

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Auto sentry eau99rAuto sentry eau99s

Table of Contents