Pan Detection; Residual Heat Indication; Booster Function - Kuppersbusch KI6520.0SF Instructions For Use Manual

Table of Contents

Advertisement

Available languages

Available languages

Pan detection

The pan detection ensures a perfect safety. The induction doesn't work:
• If there is no pan on the heating zone or if this pan is not adapted to the induction. In this
case it is impossible to increase the power and the display shows [ U ]. This symbol
disappears when a pan is put on the heating zone.
• If the pan is removed from the heating zone the operation is stopped. The display shows
[ U ]. The symbol [ U ] disappears when the pan is put back to the heating zone. The
cooking continues with the power level set before.
After use, switch the heat element off: don't let the pan detection [ U ] active.

Residual heat indication

After the switch off of a heating zone or the complete stop of the hob, the heating zones are still
hot and indicates [ H ] on the display.
The symbol [ H ] disappears when the heating zones may be touched without danger.
As far as the residual heat indicators are on light, don't touch the heating zones and don't put any
heat sensitive object on them. There are risks of burn and fire.

Booster function

The booster function [ P ] grants a boost of power to the selected heating zone.
If this function is activated the heating zones works during 5 minutes with an ultra high power.
The booster is foreseen for example to heat up rapidely big quantities of water, like nuddles cooking.
Start up / Stop the booster function :
Action
Zone selection
Increase power
Start up the booster
Stop the booster
Power management:
When it comes to the power, the cooking zones are running by pairs and cannot exceed an overall
maximum of power. If the selected heating levels for both zones exceed the maximum available
amount of power, the powermanagement function is automatically reducing the power from one of
these zones. The display of this zone is first blinling ; the level is then automatically reduced to the
highest suitable position.
Heating zone selected
[ P ] is displayed
Control panel
Press key [
]
Press key [ + ]
Press key [ + ]
Press key [ - ]
The other heating zone: (example: power level 9)
[ 9 ] goes to [ 8 ] and blinks
30
Display
[ 0 ]
[ 1 ] to [ 9 ]
[ P ] during 5 min
[ 9 ]

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ki6520.0srKi6520.0seKi6520.0wr

Table of Contents