• When disconnecting the hose coupling, hold the coupling
piece of the hose firmly with your hand. This will ensure that
you avoid injuries caused by the hose recoiling.
• Wear safety goggles when working with the air blow gun.
Minor injuries can be caused by foreign objects and blown
away parts.
• Wear safety goggles and a respirator when working with
the compressed air pistol. Dusts are harmful to health! Minor
injuries can be caused by foreign objects and blown away
parts.
• Do not blow on people or clean clothing whilst on the body
with the air blow gun. Danger of injury!
Safety instructions when using spraying attach-
ments (e.g. paint sprayers):
1.
Keep the spray attachment away from the compressor
when filling so that no liquid comes into contact with the
compressor.
2.
Never spray in the direction of the compressor when us-
ing the spraying attachments (e.g. paint sprayers). Mois-
ture can lead to electrical hazards!
3.
Do not use paints or solvents with a flash point of less
than 55°C. Risk of explosion!
4.
Do not heat paints and solvents. Risk of explosion!
5.
If harmful liquids are processed, filter devices (face
masks) are required for protection. Also observe the in-
formation on protective measures provided by the manu-
facturers of such substances.
6.
The information and labelling of the hazardous
substances ordinance affixed to the outer packag-
ing of the processed materials must be observed.
If necessary, take additional protective measures, in par-
ticular wear suitable clothing and masks.
7.
Do not smoke during the spraying process or in the work-
ing area. Risk of explosion! Paint vapours are also highly
flammable.
8.
Fireplaces, naked flames lights or sparking machinery
must not be present or operated.
9.
Do not store or consume food or drinks in the work area.
Paint fumes are harmful to health.
10. The working area must be larger than 30 m³ and suffi-
cient air exchange must be ensured during spraying and
drying.
11. Do not spray into the wind. Always observe the regula-
tions of the local police authorities when spraying flam-
mable or hazardous spraying materials.
12. Do not use media such as white spirit, butyl alcohol and
methylene chloride in conjunction with the PVC pressure
hose. These media destroy the pressure hose.
13. The work area must be separated from the compressor so
that it cannot come into direct contact with the working
medium.
Operation of pressure vessels
• Anyone who operates a pressure vessel must keep this in
good working order, operate and monitor it correctly, per-
form the necessary maintenance and servicing works imme-
diately and implement safety measures as required accord-
ing to the circumstances.
• The regulatory authority can instruct necessary monitoring
measures in individual cases.
• A pressure vessel must not be operated if it exhibits a defect
that poses a danger to personnel or third parties.
• Check the pressure vessel for rust and damage each time
before use. The compressor shall not be operated if the pres-
sure vessel is damaged or rusty. If you discover damage,
please contact the customer service workshop.
Warning!
This power tool generates an electromagnetic field during op-
eration. This field can impair active or passive medical implants
under certain conditions.
In order to prevent the risk of serious or deadly injuries, we rec-
ommend that persons with medical implants consult with their
physician and the manufacturer of the medical implant prior to
operating the power tool.
Ensure careful storage of the safety instructions.
Residual risks
The machine has been built according to the state-of-the-art
and the recognised technical safety requirements. However,
individual residual risks can arise during operation.
• Health hazard due to electrical power, with the use of im-
proper electrical connection cables.
• Furthermore, despite all precautions having been met, some
non-obvious residual risks may still remain.
• Residual risks can be minimised if the "Safety Instructions"
and the "Intended Use" together with the operating manual
as a whole are observed.
• Avoid accidental starting of the machine: the operating but-
ton may not be pressed when inserting the plug in an outlet.
Use the tool that is recommended in this operating manual.
This is how to ensure that your machine provides optimum
performance.
• Keep your hands away from the working area when the ma-
chine is in operation.

7. Technical data

Mains power connection
Engine output
Operating mode
Compressor speed
Pressure vessel volume
Operating pressure
Theo. Suction capability
Theo. Power output
Protection category
Device weight
Max. installation altitude (above sea
level)
Technical changes reserved!
* Operating mode S3, periodic intermediate duty
230 V ~ 50 Hz
1500 W
S3 25%*
4000 min
-1
ca. 50 l
ca. 10 bar
approx. 240 l/min
max. 140 l/min
IP 30
24 kg
1000 m