Advertisement

Quick Links

MA00607802
Detailed operating instructions
PD 360/8 Basic
EB10430411
PD 360/24 Basic
EB10430855
PD 360/8 Basic SMB
EB10430480
PD 360/24 Basic SMB
EB10430893
PD 360i/8 Basic
EB10430435
PD 360i/24 Basic
EB10430879
PD 360i/8 Basic SMB
EB10430473
PD 360i/24 Basic SMB
EB10430916
ESYLUX GmbH | An der Strusbek 40
22926 Ahrensburg | Germany
info@esylux.com | www.esylux.com
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PD 360/8 Basic and is the answer not in the manual?

Questions and answers

Summary of Contents for ESYLUX PD 360/8 Basic

  • Page 1 PD 360/24 Basic PD 360i/24 Basic EB10430855 EB10430879 PD 360/8 Basic SMB PD 360i/8 Basic SMB EB10430480 EB10430473 PD 360/24 Basic SMB PD 360i/24 Basic SMB EB10430893 EB10430916 ESYLUX GmbH | An der Strusbek 40 22926 Ahrensburg | Germany info@esylux.com | www.esylux.com...
  • Page 2: Table Of Contents

    Programming the Mobil-PDi/MDi-universal Technical data Troubleshooting Maintenance Cleaning ESYLUX manufacturer’s guarantee 2 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 3: Description

    OPERATING INSTRUCTIONS Description The ESYLUX ceiling-mounted presence detector is a passive infrared presence detector that responds to moving heat sources, such as people walking. The presence detector is designed for small rooms and passageways that benefit from natural light. Note: Use this product only as intended (as described in the user instructions).
  • Page 4: Operation/Functionality

    Time delay from dark to light: 5 min. = red LED flashes during this period. 4 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 5: Installation/Connection

    Surface mounting Surface mounting with spacers 5 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 6 Parallel connection Phase, 230 V Lighting Neutral conductor Push button 6 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 7: Masking The Field Of Detection

    7 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 8: Settings

    8 m may be dramatically reduced due to the sun's infrared rays. Mobil-PDi/MDi (EM10425509) 8 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 9: Mobil-Pdi/Mdi Temporary Settings

    Acknowledgement: The red LED flashes three times. 9 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 10 The sensitivity of the detector for the purpose of detecting movement can be set. Acknowledgement: The red LED flashes three times. 10 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 11: Mobil-Pdi/Mdi-Universal

    Remote control Functions Channel 1 Channel 2 System Bat ok 11 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 12 Note: The "4h ON/OFF" mode can be temporarily exited using the "Reset" function. Acknowledgement: slow flashing. Bat ok 12 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 13: Programming The Mobil-Pdi/Mdi-Universal

    Fully/semi-automatic Bat ok Light Bat ok 13 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 14 Acknowledgement: The red LED is switched off for approx. 2 seconds. 14 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 15: Technical Data

    Detector does not respond. - Check the power supply 15 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 16: Maintenance

    Please use a lint-free cloth that is either dry or dampened only with water. 16 / 17 PD 360/8 Basic PD 360i/24 Basic PD 360/24 Basic SMB PD 360i/8 Basic PD 360/8 Basic SMB PD 360i/24 Basic SMB PD 360/24 Basic PD 360i/8 Basic SMB...
  • Page 17: Esylux Manufacturer's Guarantee

    D-22908 Ahrensburg, Germany (for Germany) or the relevant ESYLUX distributor in your country (visit www.esylux.com for a complete overview) provides a guarantee against manufacturing/material defects in ESYLUX devices for a period of three years from the date of manufacture. This guarantee is independent of your legal rights with respect to the seller of the device.