Parameter Modification Procedure - Riello RS 310/EV ULX Installation, Use And Maintenance Instructions

Forced draught gas burners
Table of Contents

Advertisement

The password must only be communicated to the
qualified personnel or the Technical Assistance
Service, and must be kept in a safe place.
WARNING
Once the access procedure has been carried out, the display will
show "PArA" for a few seconds.
P
Select the group of parameters with keys "+" and "-", and con-
firm by pressing the key "i/reset".
Within the group you have chosen, scroll through the list with the
keys "+" and "-". At the end of the list, the display visualises
"End".
To return to Normal visualisation mode, simultaneously press the
keys "+" and "-" (ESC) twice.
7.1.4.2 Assigning parameter levels
The parameters level is subdivided into groups as shown in
Tab. N.
7.2

Parameter modification procedure

After accessing the level and group of parameters, the display
visualises the number of the parameter (flashing) on the left, and
the corresponding value on the right.
P
If the value is not visualised, press the key "i/reset for 1 - 3 sec-
onds.
Find below an example of how to modify the parameter relating
to the pre-purging time (No. 225).
Press the key "i/reset": the value 20 (seconds) will appear.
NOTE:
The unit of measurement of the time is not visualised but is un-
derstood in seconds.
P
/reset
Press the key "+" and increase the value to 25 seconds (flash-
ing). Press the key "i/reset" to confirm and store.
Control and display
V
h min
s
%
ESC
/reset
h
min
s
%
V
h min s
%
No.
Parameter
100: ParA
General parameters
Information and identification data of the system.
200: ParA
Checks on the burner
Type of operation, intervention and safety times
of the various phases.
400: Set
Air/fuel modulation curve
Setting of air/fuel adjustment points
Positioning of servomotors
500: ParA
Choice of positions of the air/fuel servomotors in
the various phases.
Servomotors
600: ParA
Setting and addressing of the servomotors.
700: HISt
Log of the errors:
Choice of different visualisation modes for the er-
rors log.
900: dAtA
Process information
Visualisation of information for the remote man-
agement of the burner.
All the parameters are checked in the factory.
Modification/tampering may compromise the
good operation of the burner and cause injury to
people or damage to things. In any case, modifi-
WARNING
cations must be carried out by qualified person-
nel.
To modify a parameter, refer to the "Parameter modification
procedure".
P
V
To return to the list of parameters, press the keys "+" and "-"
(ESC) simultaneously.
P
h min
7.2.0.1 Procedure for inserting and adjusting points on
the modulation curve
Nine adjustment/calibration points (P1 ÷ P9) can be inserted in
the flame control for each servomotor, varying their position by
degrees and, consequently, the quantity of air and fuel intro-
duced.
The ignition point P0 is independent of the minimum modulation
value. This means that, in the event of difficulty, it is possible to
switch on the burner at a value other than the modulation mini-
mum (P1).
To access the Parameter mode (group 400) referring to the "Ac-
cess procedure with password" on page 36.
To insert or adjust a point, proceed as follows.
Using the keys "+" and "-" insert/select the curve point you want
and wait for it to flash: this means that the servomotors are now
37
GB
h mi
s
%
s
%
Tab. N
/reset
ESC
20205882

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs 510/ev ulxS045t2S046t2

Table of Contents