STEP 1: POWER ON After the AC adapter and/or batteries are installed, and the pen probe is fully plugged into the unit, turn the AuRACLE PRO on by pushing the MODE button. The LCD display will then show “Ready”. STEP 2:...
Page 3
STEP 4: PRO POWER OFF To turn the AuRACLE PRO off, press and hold the MODE button. The tester also has an auto-off feature when using battery power and will automatically turn itself off in 10 minutes if not used.
Page 4
Replaceable pen probe provides thousands of tests with proper care • Powered by 9V alkaline battery (not included) or multi-voltage 100V-240V AC adapter • Includes: AuRACLE PRO, pen probe, jewelers file, and AC adapter • One-year limited warranty AURACLE PRO DIAGRAM 1. Backlit LCD Display 2.
Install a 9V alkaline battery (not included) as follows. First, always be mindful that the AuRACLE PRO is a delicate instrument and can be broken if it is not handled with care. Open the battery compartment door located on the bottom side of the unit by pressing and then sliding the battery compartment door off with your thumbs.
LCD display. Place the gold you are using to calibrate the AuRACLE PRO on the testing plate with the filed area facing up. Steadily touch the end of the pen probe’s felt tip to the filed area on the gold and once the process has been completed the LCD display will read “Success!”.
Once the pen probe touches the gold sample, the AuRACLE PRO will quickly monitor the readings and wait for stability before it will be considered a successful calibration.
Page 8
Since the AuRACLE PRO can be calibrated in only a matter of seconds and the pen probe’s felt tip may be quickly and easily cleaned when needed, these simple steps should be a regular part of your testing and problem-solving process.
Page 9
(example plastic). TEST RESULTS ARE TOO HIGH: This is an indication that the AuRACLE PRO is out of calibration, or perhaps there is a high presence of silver, palladium, or rhodium on the gold you are testing.
WARRANTY Your AuRACLE PRO comes with a ONE YEAR LIMITED WARRANTY against defects in materials and workmanship as determined by the factory. The pen probe is covered by a 30-DAY limited warranty against defects in materials and workmanship as determined by the factory. The pen probe is not covered against overuse, misuse and drying out due to the user not replacing the protective cap after use.